7. MAINTENANCE
The Vuelift Mini elevator is designed to require minimal maintenance.
A 6-month inspection of certain components is required to maintain the
Factory Warranty. The first required service of the drive train components
(motor/gearbox, drums, etc.) is after 2,000 operational hours (approximately
120,000 trips).
The items that need to be checked during the 6-month inspection are listed in
the Maintenance Schedule.
IMPORTANT: Please test the phone in your elevator during every maintenance.
If the phone is inactive, please shut down the elevator until the phone line is
active.
NOTE: Refer to the Maintenance Procedures for descriptions of the items.
Maintenance Procedures
INSIDE CAR
Car Interior
•
Examine the car interior for damage including the ceiling, handrails,
door panels, lighting and floor. Tighten all fasteners in the car panel
and replace as needed.
Car Controls and Panel
•
Examine the condition of the car control panels and check the
operation of all lights. Replace all burnt out lights.
Leveling, Stopping, Acceleration and Deceleration
•
Run the car to each floor in both directions to observe the leveling
accuracy, stopping, acceleration and deceleration. Adjust as needed.
Car Door Operation
•
Observe the door for proper operation including smooth movement,
starts and stops, and alignment.
Ride Floor to Floor
•
Run the car from floor to floor and observe for smooth travel and
unusual noises. Adjust or repair as needed.
Part No. 001254, 26-m4-2022
The 6-month inspection and all maintenance
procedures must be performed by a Qualified
Technician. Contact your Authorized Dealer.
Rail lubrication is NOT allowed for the Vuelift
hoistway or car rails.
Vuelift Mini Owner's Manual
15