3. OPERATION

Operating from the COP Controls

Figure 2 shows the car operating panel
(COP) controls.
To operate the Telecab17 from the COP
controls:
1 Enter the cab and close the door.
2 Insert the key into the key switch and
turn it clockwise to the operating
position. The key is in the operating
position when it cannot be pulled
out.
3 Apply constant pressure on the
appropriate Up or Down arrow
button to move the Telecab17 in the
desired direction. Note the
following:
The Telecab17 will not move if
the door is open.
The Telecab17 will stop moving
in the down direction if the
underpan sensor detects an
object underneath it.
The Telecab17 will stop moving in the up direction if it reaches the
floor plug and the floor plug sensor detects an object on it that weighs
more than 20 lb (9.1 kg).
4 When the cab reaches the landing, the door will unlock automatically.
5 Exit the cab and close the door.
6 To prevent unauthorized use of the lift, take the key out when the unit is not
in operation.
7 Pressing the Emergency Stop button during travel will stop the lift
immediately and activate the alarm. The Emergency Stop overrides the
landing station (hall call) controls. Pull the Emergency Stop out to return the
lift to normal operation.
8 Pressing the Alarm button during travel will activate the alarm. If the door is
locked at a landing, you can press the Alarm button to unlock the current
landing door.
Part No. 001081, 28-m08-2018
Figure 2
Down
Alarm
Key Switch
Emergency
Stop Button
Telecab17 Owner's Manual
7