Manual Lowering And Battery Lowering System - Savaria Telecab17 Owner's Manual

Residential elevator
Table of Contents

Advertisement

Manual Lowering and Battery Lowering System

If a power failure occurs, a battery lowering system will bring the Telecab17 to
the bottom level. If the battery fails while operating, there is also a remote
manual lowering device that you can use to lower the Telecab17 to the bottom
level.
For units with a 120V AC pump, the manual lowering box (Figure 7) is located
on the side of the Telecab17. Pull on the steel cable located inside the manual
lowering box to lower the Telecab17 to the bottom level.
Figure 7
Steel cable
For units with a 12V DC pump, there is a key switch located on the side of the
Telecab17. Insert the same key used for call/send control into the key switch
and turn it to the operating position. The cab will descend to the bottom level.
This mechanism is for emergency use only. After use of any emergency
function (access key or manual lowering device), ensure that all
doors/gates are secure and locked. While the emergency function is in
use, DO NOT leave the area unattended.
Part No. 001081, 28-m08-2018