Heavy Load Protection Function

Register
D2
D1
D0
Name
0
0
0
HLMOD
R
0
0
0
The E0C6001 has the heavy load protection function for
when the battery load becomes heavy and the source voltage
changes, such as when an external buzzer sounds or an
external lamp lights. The state where the heavy load protec-
tion function is in effect is called the heavy load protection
mode. Compared with the normal operation mode, this mode
can reduce the output voltage variation of the internal regu-
lated voltage and spend more power consumption.
The normal mode changes to the heavy load protection mode
in the following case:
• When the software changes the mode to the heavy load
protection mode (HLMOD = "1")