JEM Glaciator X-stream User Manual page 22

Hide thumbs Also See for Glaciator X-stream:
Table of Contents

Advertisement

Fog Display
Fog
Ton
ToF
Ice Display
Den
SuP
Ice
22
Sets the current Fog output level in the range 0 to 20 (0 -
100% fog output).
Sets the ON time of the Timer in the range 0 to 90
(seconds).The timer is enabled by setting the Timer switch
on the control panel to ON. While the timer is running, the
left-hand display will show the elapsed time in seconds. The
display will alternate between the period name (ton/toF) and
the elapsed time in seconds. To set the time periods, use the
Menu key on the left-hand display to access the ton or toF
menu. Press the Enter key to see the current value, and - if
needed - make adjustments using the Up/Down keys. Press
enter to store a new value. Enable the Timer switch on the
control panel to test the settings. The current Fog and
Density levels will be used by the timer system when in the
ON period.
Sets the OFF time of the Timer in the range 0 to 90
(seconds).
Sets the output density level (Lo, Nor, Hi). The Low, Normal &
High density settings are used to relate the fan speed to the
current level of fog output. Use Lo density when using ducting
to get maximum thrust from the fan, and use Hi density to
create a very dense effect (although with reduced volume).
The ramping control system may override the density setting if
required.
Sets the supply voltage in the range 200 to 250V.
Variations in pump performance due to supply frequency
differences (50/60Hz), are compensated for automatically.
Supply voltage changes will also affect the pump performance,
and can be catered for by using the this menu to adjust the
voltage to match the local power supply voltage (valid range is
200 - 250V). Press the enter key to store the new setting in
non-volatile memory. The pumps will now run at the optimum
level for the conditions.
Displays current system temperatures.
The software that controls the displays and the other functions
of the machine is stored in 'Flash' memory on the DMX
receiver PCB. As new features become available, this program
code can be updated by using the Martin Uploader
programming device for the AVR microprocessor.