52 - Adjustments And Troubleshooting
OCopyri~
1999 eeum
Automaled Enlr811Ce5ysteme, Inc. May not be reprinled wilhoot

PMD Codes, Tests and Status

PMD error codes.

Note !hat if me
than one error rode exisrs, rorrecting
!he fir.;!will let !he second display, rorrecting !he second
will let !he Ihird display, and so on until all errors codes
have been fixed.

Testing with the PMD.

The PMD can initiate some system tests.
function
99 and lhen
enler
the values
below to specify a particular
test. Press the pro-
gram button P on the PMD to start the test. If the
lest is unsuccessful
an error code will flash on the
value display.

Status codes with the PMD.

The PMD normally
shows
the following
codes during operation.
These status codes are
not error codes.
If anyone
of the status codes are
constantly
displayed
during
cycling,
sponding
inpul device has
be checked,
10
necessary remedied or replaced.
Notel
If the fault persists
and all the recommended
measures
have been
taken,
the operator
control
must be returned
well packed
factory.
Please
include
a written
of the problem
with the unit being returned.
petrTieaion.
Reason
Door opened without impulse
Mat safety error
Presence impulse error
Motor error
Revolution counter error
Control unit error
PMD error
PMD-CUP communication error
PMD access denied.
Test Of
Value
01
External program selector switch
Molor, Visual test. (leI the door close before
02
Select
commencing this test.)
shown
03
Revolution counter
04
Mat safety monitoring
05
Presence impulse monitoring
Status Code
Status
Operation ok
on
10
Search for closed position
status
Inner impulse active
11
Outer impulse active
12
Key impulse active
13
the corre-
Synchronizing
14
and if
15
Interlocking impulse active
16
Mat safely aclive
Presence detection aclive
17
18
Presence impulse active
Door blocked
19
and
Kill impulse active
20
to the
21
low speed opening/learn
description
22
Door opened with open/close
--------(
3-26-99
Error Code
50 flashing
51 flashing
52 flashing
53 flashing
54 flashing
55 flashing
69 flashing
70 flashing
71 flashing
Error Code
51 flashing
The motor nuns about 1 second in lhe opening
direction, then closes the door!s) again.
54 flashing
51 flashing
52 flashing
impulse aclive
impulse
Swingmaster
MP
US23.o186.o1
Remedies
Check why the door moved.
Check the contact mat.
Check the VPNP-S and cables.
Replace the motor.
Check revolution counter, cables.
Replace the control unit.
Replace the PMD.
Check the connections.
Return the PMD to be updated.
Remedies
Normal-
everything is OK.
let the door finish its cycle.
Check this input.
Check this input.
Check this input.
Check lhis input.
Check the conneclions.
Check this input.
Check this input.
Check lhis input.
Check for obstacles
Check this input.
let the door finish its cycle.
Close the door with new impulse.