Antifreeze and anti-corrosion agents

Pos: 3 1.45 /I nbetriebnahme - M ontage/Anschlüsse /Mechanis ch/T-Kr eis/Glykol/Frost-, K orrosionss chutz/01a - Text: e xterne Rückkühlanlage - Termotek (K ühl modul, ... ) @ 153 \mod_1 3668 73150 682_1 8.docx @ 15 5651 3 @ @ 1
Pos: 3 1.46 /I nbetriebnahme - M ontage/Anschlüsse /Mechanis ch/T-Kr eis/Glykol/Frost-, K orrosionss chutz/02 - Text: S chut z der Ba uteile KANN Syste mkreis be füllt sein @ 154\ mod_13 68540 8554 91_18 .docx @ 156 6457 @ @ 1
Pos: 3 1.47 / -- leer --/ ......... .... Absatz ... ......... @ 77\ mod_12 62789 1072 48_0. docx @ 85546 8 @ @ 1
Pos: 3 1.48 /I nbetriebnahme - M ontage/Anschlüsse /Mechanis ch/T-Kr eis/Glykol/Frost-, K orrosionss chutz04 - Achtung-Hi nweis - Glykolkonze ntration @ 17 4\ mod_1385 3838 84654 _18.docx @ 1 7618 28 @ @ 1
Pos: 3 1.49 /I nbetriebnahme - M ontage/Anschlüsse /Mechanis ch/T-Kr eis/Glykol/Frost-, K orrosionss chutz05.1 - Info Befüllung T -Kreis: Allge mein - alle @ 188 \mod_1 39513 8505 119_1 8.docx @ 18 84657 @ @ 1
Pos: 3 1.50 / -- leer --/ ......... .... Absatz ... ......... @ 77\ mod_12 62789 1072 48_0. docx @ 85546 8 @ @ 1
Pos: 3 1.51 /I nbetriebnahme - M ontage/Anschlüsse /Mechanis ch/T-Kr eis/Glykol/Frost-, K orrosionss chutzHinweis - Was serqualität gemä ß Kap. TD einhalte n @ 181 \mod_1 3896 03412 442_1 8.docx @ 18 4096 8 @ @ 1
Pos: 3 1.52 / -- leer --/ ====== == @ 1\ mod26_ 18.docx @ 2 7188 @ @ 1
Setting Up
If aluminium is used in the external water circuit, there is a risk of corrosion. In order to
avoid electrochemical corrosion, it must be checked whether the materials that are used
in the cooling module are compatible with the materials of the external cooling circuit.
The type and dose of a suitable anti-corrosion or anti-freeze agent depends on the
situation on site and also on the external re-cooling system. It must be determined by the
system planner.
The following materials are used in the cooling module.
copper
bras
stainless steel
gunmetal
In order to protect the components in the system circuit against corrosion and frost
damage, the system circuit must be filled with an anti-corrosion and anti-freeze agent.
Frost damage may be caused by contamination, air that is trapped inside the system, or by
a pump malfunction.
Notice
Damage to components
If the concentration of anti-corrosion or anti-freeze agents is too high or too low in the
circuit, components may be damaged (e.g. the seals). If the concentration is too low, the
corrosion may actually be stimulated.
When using anti-corrosion or antifreeze agents, please comply with the information
provided by the manufacturers concerning the area of application, the compatibility with
other materials, and the minimum/maximum mixing ratio, etc.
When using monoethylene glycol as the anti-corrosion and anti-freezing agent, please
observe the following points:
Do not mix anti-corrosion and anti-freezing agents of different manufacturers.
Document the name and type of the anti-corrosion and anti-freezing agent that is
used.
For filling the system control circuit with anti-corrosion and anti-freezing agents,
we recommend mixing the liquids in advance with the aid of a filling pump.
Note
In order to ensure the trouble-free operation of the unit, the water quality requirements
as stated in the "Technical data" section must be fulfilled.