Thank you for your choice of Parker product. Please read this
operating manual carefully and use the product correctly. Keep this
operating manual in case questions arise about this product in the
future. If this operating manual becomes unreadable or lost, consult
our distributors or Parker sales offices.
For Safety Use
The following safety precautions are provided to prevent damage and
injury to personnel and to provide instructions on the correct usage of
this product. These precautions are classified into 3 categories:
"CAUTION", "WARNING", and "DANGER" according to the severity
of possible injury or damage and the likelihood of such injury or
damage. Be sure to comply with all precautions. Also comply with
safety regulations such as ISO 4414(*1), Industrial Safety and Health
Law, and High Pressure Gas Safety Law.
Indicates an impeding hazardous situation which may
Danger:
arise due to improper handling or operation and could
result in serious personal injury or death.
Indicates a potentially hazardous situation which may
Warning:
arise due to improper handling or operation and could
result in serious personal injury or death.
Indicates a potentially hazardous situation which may
arise due to improper handling or operation and could
Caution:
result in personal injury or property-damage-only
accidents.
*1 ISO 4414: Pneumatic fluid power recommendations for the application of equipment to
transmission control system.
Warning
● This product is designed for air blowgun.
Do not use it for other purposes.
Use compressed air from an air compressor.
Do not use air from a high pressure tank or any other gases.
● Do not blow air from air blowgun towards
personnel or animals.
Direct air blow or substance blown by air blow can potentially
cause injury for humans or animals.
● Wear safety glasses and ear plugs.
Regardless of the use of this product, wear safety glasses and
earplugs when operating an air blowgun. Without proper
protection, injury to eyes due to blown dust or noise induced
deafness would be potentially caused.
● Do not disassemble or modify this product.
Disassembling or modification may cause safety accidents in
addition to operation failure.
Caution
● Attach a pipe fitting or joint properly.
If a pipe fitting or joint are attached improperly, it may cause
danger such as hose whip due to unplugged piping. Confirm the
connection of hose, tube or coupler joint is tight as well as the
connection to this product prior to use.
● Do not use for medical equipment or cooking
equipment
This product contains a small amount of lubricant. If there is
concern for contamination due to lubricant, do not use.
"Air Saver Module" HASV08R
Specifications
Fluid
Pressure Range
Maximum Flow
Ambient Temperature
Pulse Adjustment Range
Port Size
Weight
*1 "Maximum Flow" indicates the flow capacity of this product, and
actual flow consumption is depending on the attached air blowgun.
*2 If the temperature is under the specified temperature, pulse blow
may become unstable. Please use it as continuous blow
temporally for a while to reach specified temperature. This product
works correctly within the specified ambient temperature.
Connection
<Example of attachment>
1.
Before Piping, thoroughly flush the inside of each pipe to
remove chips, machining oil, and dust etc. If sealing tape is
used for the thread, leave 1.5 to 2 thread turns unwrapped. Do
not use liquid sealant. It has possibility to contaminate the
product and may cause malfunction.
Leave space of 1.5 -2 turns
Not good
Good
2.
When installing piping or a joint, prevent penetration of chips or
sealing agent. Also tightening torque should be within the range
9IM-E009-a
Issued:Jan.15.2016
Compressed air
3.5 to 8 bar
1300L/min (@5 bar)
*1
10 to 50 degree C
*2
5 to 15Hz
Rc1/4 (BSPT1/4)
IN
R1/4 (BSPT1/4)
OUT
155 g
Air blowgun
Reference blowgun:
Parker LEGRIS
Part Number: 0659 00 13
(Sold Separately)
"Air Saver Module"
HASV08R
Push-in fitting or joint
such as coupler
(Sold Separately)
Bits of seal tape may enter
the flow passage and cause
malfunction.
It can be used by
cutting in half.
Cut with knife.

Advertisement

loading

Summary of Contents for Parker HASV08R

  • Page 1 “Air Saver Module” HASV08R Issued:Jan.15.2016 Operating Manual Specifications Thank you for your choice of Parker product. Please read this operating manual carefully and use the product correctly. Keep this Fluid Compressed air operating manual in case questions arise about this product in the future.
  • Page 2 Discharge drain from upstream air filter periodically. If periodic R, Rc1/4 12 to 14 drain discharge is difficult, Parker recommends setting up an air An air filter (Nominal filtration rating of 5 micron or smaller) filter with automatic drain. must be placed upstream of piping. There is no need for ...