INSTALLATION AND OPERATION INSTRUCTIONS FOR ZERO CLEARANCE AND INSERT UNITS ZECL-26-2923-BG ZECL-30-3226-BG ZECL-33-3624-BG ZECL-39-4134-BG ZECL-2939-BG INSERT-26-3825-BG INSERT-30-4026-BG INSERT-33-4230-BG ZECL-26-2923-FLUSHMT-BG ZECL-30-3226-FLUSHMT-BG SAFETY INFORM ATION WARNING If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
IMPORTANT INSTRUCTIONS Read all instructions before installing or using this heater. 2. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes and curtains at least 3 feet from the front of the heater; keep them away from sides and rear as well.
UNPACKING AND TESTING APPLIANCE Carefully remove t he appliance from t he box. Remove t he packing screws from bot h sides of t he fireplace. Prior to inst alling t he appliance, t est t o make sure t he appliance operates properly by plugging t he power supply cord int o a convenient ly locat ed 120 Volt grounded out let .
A 15 ampere, 120 Volt , 60 Hz branch circuit wit h proper ground must be available at t he locat ion. Preferably a dedicat ed branch circuit should be provided t o avoid circuit breakers t o t rip of fuses t o blow.
ZECL-26-2923-BG Descript ion Built-in Appliance This appliance has been tested in Voltage 120V AC 60Hz accordance wit h t he UL St andard 2021 Watt s 1500W M ax fixed locat ion dedicated NO HEATER elect ric room appliances in t he Unit ed...
ZECL-30-3226-BG Descript ion This appliance has been t est ed Built-in Appliance accordance wit h t he UL St andard 2021 Voltage 120V AC 60Hz for fixed and locat ion dedicated elect ric Watt s 1500W M ax room appliances in t he United St at es and NO HEATER Canada.
ZECL-33-3624-BG Descript ion This appliance been tested Built-in Appliance accordance wit h t he UL St andard 2021 for Voltage 120V AC 60Hz fixed and locat ion dedicat ed elect ric room Watt s 1500W M ax appliances in t he United St ates and Canada. NO HEATER If you need assist ance during inst allat ion, M OTOR HEATER...
ZECL-39-4134-BG This appliance been t ested Descript ion Built-in Appliance accordance wit h t he UL St andard 2021 for Voltage 120V AC 60Hz fixed and locat ion dedicat ed elect ric room Watt s 1500W M ax appliances in t he Unit ed St ates and NO HEATER...
ZECL-2939-BG This appliance been t ested Descript ion Built-in Appliance accordance wit h t he UL St andard 2021 for Voltage 120V AC 60Hz fixed and locat ion dedicat ed elect ric room Watt s 1500W M ax appliances in t he Unit ed St ates and NO HEATER...
INSERT-26-3825-BG This appliance been t ested Descript ion Built-in Appliance accordance wit h t he UL St andard 2021 for Voltage 120V AC 60Hz fixed and locat ion dedicat ed elect ric room Watt s 1500W M ax appliances in t he Unit ed St ates and NO HEATER...
INSERT-30-4026-BG This appliance been t ested Descript ion Built-in Appliance accordance wit h t he UL St andard 2021 for Voltage 120V AC 60Hz fixed and locat ion dedicat ed elect ric room Watt s 1500W M ax appliances in t he Unit ed St ates and NO HEATER...
INSERT-33-4230-BG This appliance been t ested Descript ion Built-in Appliance accordance wit h t he UL St andard 2021 for Voltage 120V AC 60Hz fixed and locat ion dedicat ed elect ric room Watt s 1500W M ax appliances in t he Unit ed St ates and NO HEATER...
ZECL-26-2923-FLUSHMT-BG This appliance been t ested Descript ion Built-in Appliance accordance wit h t he UL St andard 2021 for Voltage 120V AC 60Hz fixed and locat ion dedicat ed elect ric room Watt s 1500W M ax appliances in t he Unit ed St ates and NO HEATER...
ZECL-30-3226-FLUSHMT-BG This appliance been t ested Descript ion Built-in Appliance accordance wit h t he UL St andard 2021 for Voltage 120V AC 60Hz fixed and locat ion dedicat ed elect ric room Watt s 1500W M ax appliances in t he Unit ed St ates and NO HEATER...
INSTALLATION OVERVIEW – MASONRY FIREPLACES Cover plate is required if chimney does not have suitable rain cap. There must be a minimum 1" gap between the wall and the glass surround. Do not block this gap with finishing materials or trim 2”...
INSTALLATION OVERVIEW –ZERO-CLEARANCE (METAL) FIREPLACES There must be a minimum 1" gap between the wall and the glass surround. Do not block Cover plate is required if chimney this gap with finishing materials or trim does not have suitable rain cap. The log shelf, screen, and doors (if present) must...
HARD- W IRE INSTALLATION Turn off t he appliance complet ely and let cool before servicing. Only a qualified service person should service and repair t his elect ric appliance. If it is necessary t o hard wire t his appliance, a qualified elect rician must remove t he cord connect ion, and wire t he appliance direct ly t o t he household wiring.
M EDIA OPTIONS The fireplace shipped wit h an ember log set t hat is pre-inst alled. Consumers have t heir choice of decorat ive media should t hey wish t o inst all it . Log set Installing the decorative media Log set Pour t he decorat ive media into t he t ray.
OPERATION The fireplace can be operated either by the switches located on the left bottom of the fireplace unit or by supplied remote control. Plug the fireplace into a 15 Amp wall socket. MANUAL OPERATION 1. The main power ON/OFF switch in position O, the fireplace is OFF. 2.
REMOTE CONTROL OPERATION For remote to function make sure the heater is plugged in and main power switch located on the bottom left hand side is at position I. When operating the remote make sure you point the remote to the centre of the fireplace and make sure each time you press the button the buzzer inside the unit will beep once.
INSTALLING WALL THERM OSTAT WALL THERM OSTAT W IRING DIAGRAM S NOTE: THE WALL THERM OSTAT W ILL W OKING W HEN THE HEATER ON TEM P. SETTING.PLEASE REEFER TO THE M ANUAL CONTROL AND THE REM OTE CONTROL. W ire the wall thermostat prior to installing the fireplace. WALL THERM OSTAT W IRING(24 VAC) Install Wall Thermostat per instructions provided with kit and per the follow ing information: Turn off circuit breaker.
TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE SOLUTION ’ ’ Dim or no flame Flame LED s are burnt out Inspect t he LED s and replace t hem if necessary. Back black clot h is falling off Change a new flicker and back black and roll t he flicker clot h.
SERVICE HISTORY This heat er must be serviced annually depending on usage. Date Dealer Service technician Service Performed Special Concerns Name Name NOTES:...
Need help?
Do you have a question about the ZECL-26-2923-BG and is the answer not in the manual?
Questions and answers