INSTALLATION AND OPERATION INSTRUCTIONS W M -BI-2428-VLR-BG SAFETY INFORM ATION WARNING If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or ot her flammable vapors and liquids in t he vicinit y of t his or any ot her appliance.
IM PORTANT INSTRUCTIONS Read all instructions before installing or using this heater. 2. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes and curtains at least 3 feet from the front of the heater; keep them away from sides and rear as well.
UNPACKING AND TESTING APPLIANCE Carefully remove t he appliance from t he box. Remove t he packing screws from bot h sides of t he fireplace. Prior to inst alling t he appliance, t est t o make sure t he appliance operates properly by plugging t he power supply cord int o a convenient ly locat ed 120 Volt grounded out let .
Consider a locat ion where t he fireplace screen will not be exposed t o direct sunlight from windows or doors. A 15 ampere, 120 Volt , 60 Hz branch circuit wit h proper ground must be available at t he locat ion. Preferably a dedicat ed branch circuit should be provided t o avoid circuit breakers t o t rip of fuses t o blow.
Page 6
Please see the following figures. It shows the dimension of fireplace when it install in different way. a. Fireplace with flat glass insert to the wall. b. Fireplace with curve glass insert to the wall. 18" 19 1 2 " c.
INSTALLATION-WALL M OUNT Select a locat ion t hat is not prone t o moist ure and is located at least 0.91 m or 3 feet away from combust ible mat erials such as curt ains or drapes, furnit ure, bedding, paper, et c.
W M -BI-2428-VLR-BG Descript ion Built-in or Wall mount Appliance This appliance has been tested in Voltage 120V AC 60Hz accordance wit h t he UL St andard 2021 Watt s 1500W M ax fixed locat ion dedicated NO HEATER elect ric room appliances in t he Unit ed M OTOR HEATER St ates and...
INSTALLATION OVERVIEW – MASONRY FIREPLACES Cover plate is required if chimney does not have suitable rain cap. 2” (50mm) Minimum HINT: Close and seal the damper to prevent air infiltration. Attach the "This fireplace has been altered..." plate to the fireplace (use two screws or other suitable method).
INSTALLATION OVERVIEW –ZERO-CLEARANCE (METAL) FIREPLACES Cover plate is required if chimney does not have suitable rain cap. The log shelf, screen, and doors (if present) must be removed. 2” (50mm) Minimum HINT: Close and seal the damper to prevent air infiltration. HINT: Attach the "This fireplace has been Paint the interior of the...
HARD- W IRE INSTALLATION Turn off t he appliance complet ely and let cool before servicing. Only a qualified service person should service and repair t his elect ric appliance. If it is necessary t o hard wire t his appliance, a qualified elect rician must remove t he cord connect ion, and wire t he appliance direct ly t o t he household wiring.
M EDIA OPTIONS This fireplace shipped wit h 11 pieces log set , real coal and sable. 3. Use t he new t ray glass holder bracket for t he curve glass. coal 11 piece log set sable FIRE GLASS M EDIA INSTALLATION Unplug t he unit from wall and make sure 4.
OPERATION The fireplace can be operat ed eit her by t he swit ches located on t he left front of t he fireplace unit or by supplied remot e cont rol. M ANUAL OPERATION The main power ON/ OFF swit ch in posit ion O, t he fireplace is OFF. When main power ON/ OFF swit ch is at posit ion I, t he fireplace is ready t o use.
REM OTE CONTROL OPERATION For remot e t o funct ion make sure t he heat er is plugged in and main power swit ch located on t he bott om left hand side is at posit ion I. When operat ing t he remot e make sure you point t he remote t o t he cent re of t he fireplace and make sure each t ime you press t he butt on t he buzzer inside t he unit will beep once.
INSTALLING WALL THERM OSTAT WALL THERM OSTAT W IRING DIAGRAM S NOTE: THE WALL THERM OSTAT W ILL W OKING W HEN THE HEATER ON TEM P. SETTING.PLEASE REEFER TO THE M ANUAL CONTROL AND THE REM OTE CONTROL. W ire the wall thermostat prior to installing the fireplace. WALL THERM OSTAT W IRING(24 VAC) Install Wall Thermostat per instructions provided with kit and per the follow ing information: Turn off circuit breaker.
REPLACEM ENT PARTS PART NUM BER DESCRIPTION QTY . TOP PANEL BACK TOP PANEL 601089C CIRCUIT BOARD 602067D BLOWER AND HEATER ASSEM BLY 601097 FIREPLACE BOX TOP LED STRIP 10104010 TOP LED BRACKET 601036 CONTROL PANEL 301506 REM OTE RECEIVER 10103007 POWER CORD 10104002...
TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE SOLUTION ’ ’ Dim or no flame Flame LED s are burnt out Inspect t he LED s and replace t hem if necessary. Back black clot h is falling off Change a new flicker and back black and roll t he flicker clot h.
SERVICE HISTORY This heat er must be serviced annually depending on usage. Date Dealer Service technician Service Performed Special Concerns Name Name NOTES:...