3. Braze the condenser coil inlet connection.
4. Insert the receiver pipe work onto the coil outlet and loosely secure the receiver assembly to the side sup-
port bracket with the retained hardware.
5. Braze the outlet connection to the receiver assembly.
6. Install a new filter drier.
7. Replace the liquid line cushion clamps.
8. Secure the receiver assembly to the side support bracket.
9. Pressure / leak test the coil and filter drier connections. Refer to
10. Evacuate the entire unit. Refer to
11. Slide the top and bottom drain lines back into place through the side support bracket.
12. Using the two supplied straight connectors and contact adhesive reconnect the drain lines.
13. Slide the condenser fan motor wiring harness back through the side support bracket and refit to condenser motor.
14. Replace all wire ties that were removed to properly secure the drain line and wiring.
15. Reseal the wire harness and drain line penetrations with the putty.
16. Slide the condenser fan onto the motor shaft reversed but do not secure.
17. Refit the condenser fan shroud to the unit. Use the condenser fan as a guide to ensure the shroud is prop-
erly centered around the fan.
18. Remove the condenser fan, and place it on the shaft facing the correct direction. Adjust the fan to the cor-
rect position, 37mm (1.5") from the fan shroud, see
19. Use Loctite "H" on the fan set screws, and tighten.
20. Refit left and right infill panels.
21. Refit the condenser fan grille, ensuring the grille is properly centered around the condenser fan.
22. Evacuate the entire unit. Refer to
23. Recharge the unit with the charge shown on the unit serial plate. Refer to
proper unit operation that the charge is weighed into the unit.
T-362
Section
7.6.
Figure

Figure 7.7 Condenser Fan Position

37mm (1.5")
Section
7.6.
7–12
Section
7.5.
7.7.
Fan
Shroud
Section
7.7. It is important for