Figure 4.2 Display Module

Table 4–1 Display Module LEDs
LIGHT
COOL
Energized when the refrigerant compres-
(White / Blue)
sor is energized.
HEAT
Energized to indicate heater operation in
(Orange)
heat mode, defrost mode, or dehumidifica-
tion.
DEFROST
Energized when the unit is in defrost
(Orange)
mode.
IN RANGE
Energized when the controlled tempera-
(Green)
ture probe is within specified tolerance of
setpoint. The controlling probe in perish-
able range is the SUPPLY air probe and in
frozen range is the RETURN air probe.
SUPPLY
Energized when the supply air probe is
(Yellow)
used for control. When this LED is illumi-
nated, the temperature displayed in the
AIR TEMPERATURE display is the read-
ing at the supply air probe. This LED will
flash if dehumidification or humidification
is enabled.
RETURN
Energized when the return air probe is
(Yellow)
used for control. When this LED is illumi-
nated, the temperature displayed in the
AIR TEMPERATURE display is the read-
ing at the return air probe.
ALARM
Energized when an active or inactive shut-
(Red)
down alarm is in the alarm queue.
T-362
FUNCTION

Figure 4.3 Keypad

Table 4–2 Keypad Function
KEY
CODE SELECT Access function codes.
PRE-TRIP
Display Pre-Trip selection menu. Discon-
tinue pre-trip in progress.
ALARM LIST
Display alarm list and clear alarm queue.
MANUAL
Display selected defrost mode. Press and
DEFROST /
hold this key for five seconds to initiate de-
INTERVAL
frost using same logic as if the optional
manual defrost switch was toggled on.
ENTER
Confirm a selection or save a selection to
the controller.
Arrow Up
Change or scroll a selection up. Pre-trip
advance or test interrupt.
Arrow Down
Change or scroll selection down. Pre-trip
repeat backward.
RETURN /
Display non-controlling probe tempera-
SUPPLY
ture (momentary display).
°C / °F
Display alternate english / metric scale
(momentary display). When set to F,
pressure is displayed in psig and vacuum
in "/hg." "P" appears after the value to in-
dicate psig and "i" appears for inches of
mercury. When set to C, pressure read-
ings are in bars. "b" appears after the val-
ue to indicate bars.
BATTERY
Initiate battery backup mode to allow set-
POWER
point & function code selection if AC
power is not connected.
ALT MODE
Switch the functions from temperature
software to DataCORDER software. The
remaining keys function the same as de-
scribed above except the readings or
changes are made to the DataCORDER
programming.
4–2
CODE
PRE
SELECT
TRIP
MANUAL
ALARM
DEFROST/
LIST
INTERVAL
ENTER
RETURN
C
SUPPLY
F
BATTERY
ALT
POWER
MODE
FUNCTION