Technical Specifications - Progressive Dynamics PD1200 Series Installation And Operation Manual

Pure sine wave inverters

Advertisement

Troubleshooting
Symptom
Corrective Actions
During startup the inverter draws a small amount of current to charge the input capacitors. If that current exceeds a normal
range the inverter shuts down and reports an internal error. This is can be indicative of bad input wiring or an internal failure.
E-5 is displayed
Likely, DC Input power is not being properly applied to the DC input terminals.
Inverter is off. Noth-
ing happens when-
power button is
pressed
Something has interrupted the communication between the display and the inverter.
Inverter turned off for
seemingly no reason
A buzzing sound may be produced during large surges in output power. This will most commonly be observed on some refrig-
Inverter is making a
erators when the compressor is starting up. This buzzing sound is normal and should not last for more than 2 seconds
buzzing sound
For Further Assistance Contact:
PDI Service Department
(269) 781-4242
Specifications
Dimensions
Net Weight
Output Voltage
Output Power (Continuous)
Output Power (Peak)
Frequency
Waveform
Peak Efficiency
Ensure all DC input connections are tightened
Make sure DC input wire size and length comply with Figure 15
Ensure all DC input connections are tightened
Ensure that all any external DC disconnect switches are in the on position
Ensure that the DC input wires are connected to positive and negative correctly (not reversed)
If using the remote display panel, make sure that it is connected to the inverter using the provided 25' cable
Ensure that the equipment ground wire is properly secured to the equipment ground lug
Physical
L = 11.6" (294.6 mm)
W = 10.6" (269.2 mm)
H = 4.0" (101 mm)
7 lbs (3.2 kg)
AC Output
120 VAC
1000 W
2000 W
60 Hz
Pure Sine Wave
90%
Troubleshooting Guide
WARNING: FIRE, SHOCK, OR ENERGY HAZARD
DO NOT disassemble the inverter. It does not contain any user service-
able parts. Attempting to service the unit yourself could result in an
electrical shock or burn.
Failure to follow these instructions may result in serious injury or
death.
SPECIFICATIONS
Transfer Voltage
Transfer Time
Pass Through Ampacity
Under-Voltage Shutdown
Under-Voltage Restart
Over-Voltage Shutdown
Over-Voltage Restart
Nominal Voltage
Nominal Current @ max load
Transfer Switch
100 VAC
< 50 msec
15 AAC
DC Input
10.5 VDC
12.0 VDC
15.5 VDC
15.0 VDC
12.0 VDC
100 ADC
16