Installation and Operation Guide for
PD1600 Series Pure Sine Wave Inverters
Member
The PD1600 Series Inverters are 120 VAC, 60 Hz, pure sine wave inverters with integrated transfer switch. Available in 1000W, 1800W,
and 2000W models, the PD1600 Series Inverters have been robustly designed with safety and protection features for installation in recrea-
tional and commercial vehicles. With a built in transfer switch this inverter can switch seamlessly between inverter power and external
shore power without any power interruptions. It has been UL458 certified in both the US and Canada so you can feel comfortable knowing
that your inverter is safe.
With the recreational and commercial vehicle industry in mind, the PD1600 Series Inverter was designed to be compact and light-weight to
fit the strict size and weight constraints often found within vehicles. The improved thermal design reduces the ventilation space required,
which contributes to a even smaller space requirement for your inverter.
Progressive Dynamics, Inc. has a complete line of power products for your commercial and recreational vehicle needs. PDI has existing
product lines of Power Converters, Automatic Transfer Switches, AC Distribution Panels, and DC Distribution Panels. These product lines
along with the newly introduced inverters make Progressive Dynamics the only part supplier you need to build a complete power system
for your recreational or commercial vehicle. Our experienced sales and service department are available to help determine which power
solutions are best suited to your needs.
© 2019 Progressive Dynamics Enterprises, LLC. All rights reserved.
701580 Rev. B

Advertisement

loading
Need help?

Need help?

Do you have a question about the PD1600 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Progressive Dynamics PD1600 Series

  • Page 1 Member The PD1600 Series Inverters are 120 VAC, 60 Hz, pure sine wave inverters with integrated transfer switch. Available in 1000W, 1800W, and 2000W models, the PD1600 Series Inverters have been robustly designed with safety and protection features for installation in recrea- tional and commercial vehicles.
  • Page 2: Table Of Contents

    RV-C Connectivity Specification ..............16 LIMITED WARRANTY LIMITED WARRANTY: Progressive Dynamics Warrants its power inverters to be free from defects in material or workmanship under normal use and ser- vice; and limits the remedies to repair or replacement. DURATION: This warranty shall extend for a period of two years from the original date of purchase, and is valid only within the continental limits of the United States and Canada.
  • Page 3 Figure 1 PD1600 Series Inverter Components *Inverter units available with optional input power cord in- stalled All products include a quick reference guide with specifications and installation instructions NOTE: If any of the items are missing, contact Progressive Dynamics for replacement.
  • Page 4: Introduction

    Knockout to be removed when connecting to hardwired AC Output AC/DC Access Panel: Remove access panel to wire install AC and DC wiring Equipment Ground Lug: Connect case to earth ground to ensure proper, safe operation On-Board Display: Display monitors all relevant parameters of the PD1600 Series Inverter...
  • Page 5: Key Features

    Pure Sine Wave Output Under/Over Voltage Protection The output of the PD1600 Series inverter is a 120 VAC, 60 Hz, pure To protect both the inverter and the battery bank the PD1600 Series In- verter has been designed with integral under voltage and over voltage sine wave.
  • Page 6: Rv Power System

    The PD1600 Series Inverter in a 30A RV Power System PD60 SERIES DC GROUND TO DC LOADS DC DISTRIBUTION PANEL GROUND SHORE CONNECTION PD9200 SERIES CONVERTER 12V BATTERY BANK SHORE SHORE GENERATOR PD51 SERIES AC OUT TRANSFER SWITCH PANEL PANEL...
  • Page 7 The PD1600 Series Inverter in a 50A RV Power System PD60 SERIES DC GROUND TO DC LOADS DC DISTRIBUTION PANEL GROUND GENERATOR SHORE CONNECTION PD9200 SERIES CONVERTER Battery Bank AC OUT AC IN PD52 SERIES GROUND PD1600 SERIES TRANSFER SWITCH...
  • Page 8 The PD1600 series inverters have been tested and are compatible with the following Ground-Fault-Circuit-Interrupter (GFCI) receptacles. It is recommended that the PD1600 series inverter be used in conjunction with those listed below, for best performance. Other types may fail to operate properly when connected to this inverter.
  • Page 9 4. If mounting vertically, mount the PD1600 Series Inverter that the wiring compartment is facing down (see Figure 5). This will ensure that the display will be oriented correctly. It is best to ensure that PD1600 series inverter is placed in an area that keep dust & debris from entering the fan area.
  • Page 10 DC Lugs Ground Lug AC Wiring Ground Wiring DC Wiring Figure 8 Electrical Connections Side View PD1600 series Inverters are compatible with BOTH Lithium and Lead Acid batteries. Figure 9 Electrical Connections Top View ELECTRICAL CONNECTION INFORMATION STRIP LENGTH CONNECTION INFO WIRE LENGTH MIN.
  • Page 11: Installation Instructions

    Types of AC Strain Reliefs The PD1600 Series Inverter includes knockouts for use with a standard 3/8” trade size strain relief. Use of a strain relief is required when hard wiring your inverter. Neglecting to use a strain relief may cause undue stress and fatigue to the wiring connections on your unit. PDI lists examples of some commonly utilized types of strain relief.
  • Page 12 Description Code Low battery volt- Input voltage has dropped beneath 10.5V for age detected several seconds. The PD1600 Series inverter will automatically restart when the input voltage reaches 12.0V. High battery volt- Input voltage has surpassed 15.5V. The age shutdown...
  • Page 13  Indicators in sleep mode will be noticeably dimmer than in any other state  The PD1600 Series Inverter display automatically enters sleep mode when neither of the control buttons have been pressed for 30 seconds  The inverter will automatically exit sleep mode when any error occurs or shore power is detected ...
  • Page 14: Troubleshooting

    Corrective Actions The inverter has detected a fault condition. 30 Seconds after the fault condition is detected the display enters sleep mode. PD1600 Series In-  Press the select button to view the error code. Press the select button again to view the battery voltage. Proceed to the verter has a flashing correct troubleshooting action below.
  • Page 15 Troubleshooting Troubleshooting Guide Symptom Corrective Actions During startup the inverter draws a small amount of current to charge the input capacitors. If that current exceeds a normal range the inverter shuts down and reports an internal error. This is can be indicative of bad input wiring or an internal failure. E-5 is displayed ...
  • Page 16: Rv-C Connectivity Specification

    Series Inverters were released with limited functionality to turn on/off the inverter and report back basic operating parameters. Additional functionality will be added to the PD1600 Series Inverters as required to operate with modern RV multiplexing systems. See chart below for the current list of compatible Data Groups.