Types of AC Strain Reliefs
The PDI inverter includes knockouts for use with a standard 3/8" trade size strain relief. Use of a strain relief is required when hard wiring
your inverter. Neglecting to use a strain relief may cause undue stress and fatigue to the wiring connections on your unit. PDI lists examples
of some commonly utilized types of strain relief. Strain reliefs are not provided with purchase of the inverter, and must be provided by in-
staller at the time of installation.
The type of 3/8" trade size strain relief used is ultimately at the discretion of the installer. PDI can only recommend
types of strain relief for end use, and is not responsible for any misuse or absence of strain relief at installation.
Push-In Style
Halex #27510 or equivalent
3/8" trade size push–in connector
Material: Plastic

Installation Instructions

1.
Insert strain relief into 3/8" trade size opening
2.
Push wire into slotted opening the desired distance
3.
Push stripped wires into terminals blocks
4.
Install wiring into terminal blocks
Metal Clamp Style
Halex #20570 or equivalent
3/8" trade size clamp combination connector
Material: Zinc plated metal
Installation Instructions
1.
Insert strain relief into 3/8" trade size opening
2.
Slide wire through central opening
3.
Push stripped wires into terminals blocks
4.
Tighten the strain relief using screws on the side
Plastic Clamp Style
Halex #27515 or equivalent
3/8" trade size clamp combination connector
Material: Plastic
Installation Instructions
1.
Insert strain relief into 3/8" trade size opening
2.
Slide wire through central opening
3.
Push stripped wires into terminals blocks
4.
Tighten the strain relief by sliding retention clip into the slot
Figure 11
Recommend Strain Relief
11