The PD1600 Series Inverters are 120 VAC, 60 Hz, pure sine wave inverters with integrated transfer switch. Available in 1000W, 1800W,
and 2000W models, the PD1600 series inverters have been robustly designed with safety and protection features for installation in recrea-
tional and commercial vehicles. With a built in transfer switch, this inverter can switch seamlessly between inverter power and external
shore power without any power interruptions. It has been UL458 certified in both the US and Canada, so you can feel comfortable knowing
that your inverter is safe.
With the recreational and commercial vehicle industry in mind, the PD1600 series inverter was designed to be compact and light-weight to
fit the strict size and weight constraints often found within these vehicles. The improved thermal design reduces the ventilation space re-
quired, which contributes to an even smaller space requirement for your inverter.
Progressive Dynamics, Inc. has a complete line of power products for your commercial and recreational vehicle needs. PDI has existing
product lines of power converters, automatic transfer switches, AC distribution panels, and DC distribution panels. These product lines,
along with the newly introduced inverters, make Progressive Dynamics the only part supplier you need to build a complete power system
for your recreational or commercial vehicle. Our experienced sales and service department are available to help determine which power
solutions are best suited to your needs.
© 2022 Progressive Dynamics Enterprises, LLC. All rights reserved.
701580H

Advertisement

loading

Summary of Contents for Progressive Dynamics PD1618

  • Page 1 AC distribution panels, and DC distribution panels. These product lines, along with the newly introduced inverters, make Progressive Dynamics the only part supplier you need to build a complete power system for your recreational or commercial vehicle. Our experienced sales and service department are available to help determine which power solutions are best suited to your needs.
  • Page 2: Table Of Contents

    RV-C Connectivity Specification ..............16 LIMITED WARRANTY LIMITED WARRANTY: Progressive Dynamics warrants its power inverters to be free from defects in material or workmanship under normal use and service; and limits the remedies to repair or replacement. DURATION: This warranty shall extend for a period of two years from the original date of purchase, and is valid only within the continental limits of the United States and Canada.
  • Page 3 Figure 1 PD1600 Series Inverter Components *Inverter units available with optional input power cord in- stalled All products include a quick reference guide with specifications and installation instructions NOTE: If any of the items are missing, contact Progressive Dynamics for replacement.
  • Page 4: Introduction

    Introduction Figure 2 PD1600 Series Inverter (AC/DC End View) Figure 4 PD1600 Series Inverter (Isometric View) Figure 3 PD1600 Series Inverter (Fan End View) Descriptions DC Input Port (negative): Used to connect to battery (-) Ventilation Input: Ensure ventilation input is not blocked for proper operation DC Input Port (positive): Used to connect to battery (+) AC Input Knockout:...
  • Page 5: Key Features

    Thermally-Controlled Variable Speed Fan The PD1600 series inverter is designed to be being used with a hard- Using technology that is found in all Progressive Dynamics convert- wired output. If a GFCI output on the inverter is required in your...
  • Page 6: Rv Power System

    The PD1600 Series Inverter in a 30A RV Power System PD60 SERIES DC GROUND TO DC LOADS DC DISTRIBUTION PANEL GROUND SHORE CONNECTION PD9200 SERIES CONVERTER 12V BATTERY BANK SHORE SHORE GENERATOR PD51 SERIES AC OUT TRANSFER SWITCH PANEL PANEL AC IN NOTE: REFER TO WIRING DIAGRAM INCLUDED...
  • Page 7 The PD1600 Series Inverter in a 50A RV Power System PD60 SERIES DC GROUND TO DC LOADS DC DISTRIBUTION PANEL GROUND GENERATOR SHORE CONNECTION PD9200 SERIES CONVERTER Battery Bank AC OUT AC IN PD52 SERIES GROUND PD1600 SERIES TRANSFER SWITCH INVERTER GROUND MAIN NEUTRAL...
  • Page 8 Recommended GFCI for use with PD1610 Inverter: Leviton GFTR2 (20A), Eaton SGF20 (20A), Bestten USP-20A-20-PKB (20A), Hongki TST20 (20A), Zhangjiagang City Barep Technology Co. YGH-094 (20A), Recommended GFCI for use with PD1618/20 Inverter: Siemens QF130A (30A)
  • Page 9 Mounting Instructions Mounting Instructions Remove the PD1600 series inverter from its packaging, verify that all components are present, and record the inverter serial number in the quick reference guide contained within. Select an appropriate mounting location and orientation (See Page 8 for additional details regarding acceptable installation practices). Use the inverter as a drill guide by placing it flush against the mounting surface and marking the appropriate hole locations in the mounting surface (see Figure 7).
  • Page 10 Tighten strain relief (if applicable) Connect DC terminals (positive and negative) to battery with properly sized wires, 5/32” hex (PD1610); 1/4” hex (PD1618/20) When connecting DC wires a small spark may occur. This is normal charging of the inverter’s internal capacitors 10.
  • Page 11: Installation Instructions

    Types of AC Strain Reliefs The PD1600 series inverter includes knockouts for use with a standard 3/8” trade size strain relief. Use of a strain relief is required when hard wiring your inverter. Neglecting to use a strain relief may cause undue stress and fatigue to the wiring connections on your unit. PDI lists examples of some commonly utilized types of strain relief.
  • Page 12 Display Interface Select Button Display Power Button PDI Comm Port RV-C Comm Port ERROR CODES Error Condition Description Code Low battery volt- Input voltage has dropped beneath 10.5V for age detected several seconds. The PD1600 series inverter will automatically restart when the input voltage reaches 12.0V.
  • Page 13 Display Operation DC Input Voltage  Battery indicator is illuminated  Volts indicator is illuminated  DC Input Voltage measurement is always available  DC Input Voltage measurement is the default display state on start up AC Output Voltage  AC indicator is illuminated ...
  • Page 14: Troubleshooting

    Troubleshooting Troubleshooting Guide Symptom Corrective Actions The inverter has detected a fault condition. 30 Seconds after the fault condition is detected the display enters sleep mode. PD1600 series inverter  Press the select button to view the error code. Press the select button again to view the battery voltage. Proceed to the cor- has a flashing fault rect troubleshooting action below light...
  • Page 15 Troubleshooting Troubleshooting Guide Symptom Corrective Actions Something unexpected happened during the operation of the inverter.  E-5 is displayed Check all connections including the wire harness between the remote and the inverter  Call the PDI service department A short circuit has been detected on the AC output of the inverter. ...
  • Page 16 Specifications SPECIFICATIONS PHYSICAL SPECIFICATIONS TRANSFER SWITCH PD1610 PD1618 PD1620 PD1610 PD1618 PD1620 L:11.2”(284mm) L:15.0”(381mm) L:15.0”(381mm) Transfer Voltage 95 - 135 VAC Dimensions W:6.7”(170mm) W:7.9”(200mm) W:7.9”(200mm) Transfer Time < 50 msec H:4.0”(101mm) H:4.0”(101mm) H:4.0” (101mm) Pass Through 11 lbs (5.0 kg) 11 lbs (5.0 kg)
  • Page 17: Rv-C Connectivity Specification

    RV-C Connectivity Specification CAN-H CAN-L RV-C Introduction The PD1600 series inverter was designed to include RV-C communi- cations capability. RV-C is an industry developed communications protocol that is used in many RV multiplexing systems. The PD1600 series inverters were released with limited functionality to turn on/off the inverter and report back basic operating parameters.
  • Page 18 Periodic Send Description When requested the inverter responds with the make and model Product ID “Progressive Dynamics PD1600 Series vX.XX” 4 seconds Provides information on Service Points in the event of a fault DM RV The PD1600 Series inverter selects its address dynamically ensuring Address Claimed that it doesn’t claim the same source address as another device...