Download Print this page

Progressive Dynamics PD1200 Series Installation And Operation Manual page 10

Pure sine wave inverters

Advertisement

AC Connection Instructions
AC Input
Hardwired AC Connection Instructions
NOTE: Hardwired AC connection is not necessary. To avoid un-necessary debris, only remove knockouts if your installation requires use
of the AC hardwired connections.
1.
Ensure all power sources are disconnected from the inverter.
2.
Remove the AC Wiring Cover by removing 2 AC access Panel Screws.
3.
Verify that all power sources have been disconnected from the inverter by locating the green LED next to the both AC terminals. If
the LED is lit STOP, re-secure the AC access panel, then locate and remove the active power source before proceeding.
4.
Remove AC Input knockouts and AC Output knockouts by pressing firmly on the AC knockout. Bend the tab back and forth several
times to weaken the metal attachment. Knockout should snap off easily.
5.
Install 3/8" trade strain relief in AC Input and AC Output ports. See page 11 for suggested strain relief types.
6.
Strip AC wiring. See Figure 6 for recommended wire size and strip lengths.
7.
Connect AC Output terminal block (Ground, Neutral, and Line) to load wiring with properly sized wires. Terminal blocks are color
coordinated to minimize errors in installation (Black = Hot, Green = Ground, White = Neutral).
8.
Connect AC Input terminal block (Ground, Neutral, and Line) to AC input wiring with properly sized wires. NOTE: Verify AC input
wiring is not connected to AC source during installation. Terminal blocks are color coordinated to minimize errors in installation
(Black = Hot, Green = Ground, White = Neutral).
9.
Tighten strain relief (if applicable).
10. Re-install the AC Wiring Cover and secure 2 AC access panel
Screws.
MINIMUM RECOMMENDED AC WIRE SIZE STRIP LENGTH
#14 AWG Solid Wire
Stranded wire may be used with a corresponding ferrule
Figure 10
NOTICE: EQUIPMENT DAMAGE
Do not connect any AC source (such as generator or utility power) to
the AC output wiring of the inverter. Connecting an AC source to the
AC Output of the inverter will result in hazardous conditions.
Any directly wired AC Input and AC Output wiring must be protected
with properly sized circuit protection (fuses or circuit breakers).
Failure to follow these instructions may damage the unit and/or
equipment.
AC Wiring Cover
Figure 9
AC Connections Side View
Strip 0.6" (15 mm) insulation from
each cable prior to installation. Do
not leave excess copper exposed.
AC Wiring Requirements
GFCI Output (Optional)
Recommended GFCI for use with Inverter:
ZHANGJIAGANG CITY BAREP TECHNOLOGY CO., LTD
Model: YGB-094
WARNING: FIRE, SHOCK, OR ENERGY HAZARD
Make sure wiring is disconnected from all electrical sources before
handling. All wiring must be done in accordance with local and national
electrical wiring codes.
DO NOT disassemble the inverter. It does not contain any user service-
able parts. Attempting to service the unit yourself could result in an
electrical shock or burn.
Failure to follow these instructions may result in serious injury or
death.
10
AC Output

Hide quick links:

Advertisement

loading