DESCRIPTION:
The ST10-2G series steamer is a pressureless steam
cooker consisting of two independently controlled com-
partments enclosed in a single cabinet. Each compart-
ment is equipped with a separate heavy duty door with
inner gasket plate isolated from the exterior surface. Door
latches operate by action for positive sealing of inner
door. Operation controls are displayed on a single front-
mounted panel and include separate timers with indicator
lights for selection of constant steam or 60-minute-long
duration cooking. Two gas fired, stainless steel genera-
tors operating at "0" psi (0 kg/cm2) and rated at 95,000
BTU are located in the bottom cabinet and may be oper-
ated separately.
BASIC FUNCTIONING:
The steamer may be operated with only one compart-
ment in use; or both may be used simultaneously. Each
compartment is equipped with identical controls, allowing
selection of constant steam or 60-minute timer operation.
The cooker becomes operational when it is set to con-
stant steam, or the timer is set at the desired cooking time
and the compartment door is closed.
When steam flowing inside the compartment has raised
the interior temperature to 195°F, the contacts of a ther-
mostatic switch close, completing the circuit to the timer
motor and starting the cooking time period. At the end of
the set interval, timer contacts switch to shut off the cook-
ing operation and sound a signal buzzer. The buzzer is
silenced by returning the timer dial to the OFF position. In
the constant steam mode, operation will be continuous.
Steam emitted from the compartment along with liquid
cooking drainage is directed through a drain screen inside
the compartment into the cooker drain line to the genera-
tor drain box that is automatically actuated by a thermo-
static cooling valve to condense the steam to water prior
to discharge into the floor drain.
GAS OPERATION
190,000 BTU
Natural gas.
L.P. gas.
Gas fired, stainless steel steam generator(s) operating at
0 psi (0 kg/cm2) with controls equipped for operation on
120 V, 1 pH, 60 Hz.
PAN CAPACITY
1"
2-1/2"
20
STANDARD FEATURES
De-lime mode power setting
Constant Steam
Automatic blow-down
Split water lines
Thermostatically controlled drain
Single drain connection
Electronic ignition
2 rear flanged feet
Redundant controls and generator for each compart-
ment
All stainless steel constructed steam generator(s)
Safety relief valve
Left side access panel
De-liming ports on front of each generator
3

Introduction

PAN DEPTH
4"
10
6
INSTALLATION
6"
4