Cage
cage:1
Cage
cage:1

Cage Suggested Action 2

A cage power supply or power supply fan is failed, is missing input AC power, or the switch is
turned OFF. The showcage -d cageX and showalert commands provide more detail.
cli% showcage -d cage1
Id Name
LoopA Pos.A LoopB Pos.B Drives Temp
1 cage1 0:0:2
-----------Cage detail info for cage1 ---------
Interface Board Info
Link A RXLEDs
Link A TXLEDs
Link B RXLEDs
Link B TXLEDs
LED(Loop_Split)
LEDS(system,hotplug) Amber,Off Amber,Off
-----------Midplane Info-----------
Firmware_status
Product_Rev
Loop_Split
VendorId,ProductId
Unique_ID 10320300000AD000
Power Supply Info

Cage Example 3

Component -Identifier- --------------Description----------------
Cage
cage:1

Cage Suggested Action 3

When a servicecage operation is started, it puts the targeted cage into servicing mode and
illuminates the hot plug LED on the FCAL module (DC1, DC2, DC4), and causes I/O to be routed
through the other path. When the service action is finished, the servicecage endfc command
should be issued to return the cage to normal status. This checkhealth exception is reported if
the FCAL module's hot plug LED is illuminated or if the cage is in servicing mode. If a maintenance
activity is currently occurring on the drive cage, this condition may be ignored.
NOTE:
The primary path can be seen by an asterisk (*) in showpd's Ports columns.
cli% showcage -d cage1
Id Name
LoopA Pos.A LoopB Pos.B Drives Temp
1 cage1 0:0:2
-----------Cage detail info for cage1 ---------
Interface Board Info
Link A RXLEDs
Link A TXLEDs
Power supply 0's AC state is Failed
Power supply 2 is Off
0 1:0:2
0
FCAL0
Green
Green
Off
Off
Off
Current
2.37
State
Normal Op
3PARdata,DC2
State Fan State
ps0 Failed
OK Failed
ps1
OK
OK
ps2
Off
OK
ps3
OK
OK
Cage has a hotplug enabled interface card
0 1:0:2
0
FCAL0
Green
Green
RevA RevB Model Side
24 27-39 2.37 2.37 DC2
FCAL1
Off
Off
Green
Green
Off
0
AC Model
POI <AC input is missing
OK
POI
OK
POI <PS switch is turned off
OK
POI
RevA RevB Model Side
24 28-40 2.37 2.37 DC2
FCAL1
Off
Off
Troubleshooting Storage System Components
n/a
n/a