"The storage system found an error while checking cage health. There is a problem with a
drive cage that has had a firmware upgrade. Cage {0} did not come back after the firmware
upgrade. Contact HP support for help."
This error message displays in a dialog box with Retry and Cancel buttons. This error might
occur after the drive cages have had a firmware upgrade. {0} will be the name of the cage
with the problem. Contact HP Support.
For information about contacting HP Support, see
(page
54).
"The storage system found an error while checking disk health. Details are listed below."
This error message displays in a dialog box with Retry and Cancel buttons. Information listed
below the message is the CLI output for the chechhwconfig command, which occurs when
the SP does not recognize the command, allowing you to see the output.
For information about contacting HP Support, see
(page
54).
Error Strings specific to network progress step
"Unable to set the storage system network configuration. The storage system's admin volume
has not been created. This must be created before any networking information is set. Contact
HP support for help."
This message displays in a dialog box with Retry and Cancel buttons. This error occurs if a
previous command failed and the wizard did not detect the error, or if the system is rebooted
for any reason during the installation. Click Cancel to close the wizard, and then begin the
setup process again.
For information about contacting HP Support, see
(page
54).
"Unable to set the storage system network configuration. An invalid name was specified. A
storage system name must start with an alphanumeric character followed by any combination
of the following characters: a-z, A-Z, 0-9, period (.), hyphen (-), or underscore (_)."
This message displays in a dialog box with Retry and Cancel buttons. A storage system name
must contain at least 6 characters, must begin with an alphanumeric character, and must
include at least one of each of the following characters: lowercase letters (a-z); uppercase
letters (A-Z); numbers (0-9); and a period (.), a hyphen (-), or an underscore (_).
Click Cancel to close the wizard, and then begin the setup process again.
"Unable to set the storage system network configuration. An invalid IPv4 address was
specified."
This message displays in a dialog box. The error occurs if the storage system detects that the
defined storage system name is invalid.
Click Back and specify a valid IPv4 address.
"Unable to set the storage system network configuration. An invalid subnet was specified."
This message displays in a dialog box. The error occurs if the storage system detects that the
defined subnet address is invalid.
Click Back and specify a valid subnet address.
"Unable to set the storage system network configuration. An invalid IPv4 gateway was
specified."
This message displays in a dialog box. The error occurs if the storage system detects that the
defined IPv4 gateway address is invalid.
Click Back and specify a valid IPv4 gateway address.
52
Troubleshooting
"Contacting HP Support about System Setup"