Troubleshooting

If the camera cannot be
connected
If the live image screen does not appear when
you type the camera's IP address into the
location bar of the web browser, check the
following items.
Is the Ethernet cable connected correctly?
If the cable is not connected correctly, the link
indicator at the rear of the camera will not be
illuminated. Check the cable connection.
Note: Cross-type and straight-type Ethernet
cables are available. To connect the
camera directly to a computer, you need
to use a cross-type cable.
Is the link indicator flashing?
If the link indicator is illuminated steadily, it
means that the cable is connected to the camera
but communication is not possible.
The default network settings for the camera are
as follows.
IP address: 192.168.0.2
Subnet mask: 255.255.255.0
Gateway: 192.168.0.1
Port number: 80
English

If you forget the IP Address

If you forget the camera's IP address, you can
check it using the following procedure.
A Check Using the Communication
Setting Switch at the Rear of the
Camera.
1
Set the switch 1 of the communication
setting switch at the rear of the camera to
the "MODEM" setting, turn off the
camera's power, wait three seconds or
more and then turn the power back on.
2
Set the switch 1 of the communication
setting switch at the rear of the camera to
the "PC" setting, turn off the camera's
power, wait three seconds or more and
then turn the power back on.
3
Set the computer's IP address to
"192.168.0. ".
Enter a spare number that is 3 or greater as
the host address.
4
Start the web browser and point it to
"http://192.168.0.2/".
5
Check the network settings. (p. 20)
6
Turn on and off the camera's power.
7
Return the computer's IP address to its
original setting.
Note:
If the password for the Administrator level ID
has been changed, be careful not to forget
the password.
Check that none of the other devices that are
connected to the network have a duplicate IP
address of "192.168.0.2".
– 73 –