W ORKSHEET for ∗ ∗ ∗ ∗ 80 OUTPUT FUNCTION PROGRAMMING
!
Fill in the required data on the worksheet below and follow the programming procedure in the installation manual as you
enter the data during the displays and prompts that appear in sequence.
Notes: 1. For Relays, 4229 and 4204 devices are programmed in *79, *80, and *81 modes.
2. For Powerline Carrier devices (plcd), field
3. Tampers of expansion units cannot be used to operate devices.
Output
Activation Type and Detail
Function
Activated by
Zone List
Number
0=delete
(ZL)
(V20P=1-48)
1=zn list
1-8 = list
(V15P=1-24)
2=zn type
3=zn no.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
ZONE TYPE/SYSTEM OPERATION – Choices for Zone Types are:
00 = Not Used
05 = Trouble Day/Alarm Night
01 = Entry/Exit#1
06 = 24 Hr Silent
02 = Entry/Exit#2
07 = 24 Hr Audible
03 = Perimeter
08 = 24 Hr Aux
04 = Interior Follower
09 = Fire
Choices for System Operation are:
20 = Arming–Stay
21 = Arming–Away
22 = Disarming (Code + OFF)
31 = End of Exit Time
32 = Start of Entry Time
33 = Any Burglary Alarm
36 = **At Bell Timeout***
,
Partition
Number
Zone Type
Zone No.
(P)
(ZT)
(ZN)
(see table
00=none
(if using ZT trig)
0 = any
below)
V20P: 01-64
1 = partition 1
V15P: 01-06,
2 = partition 2
09-34, 49-56
3 = common
10 = Interior w/Delay
12 = Monitor Zone
14 = Carbon Monoxide§§
16 = Fire w/Verification
23 = No Alarm Response
38 = Chime
58 = Duress
39 = Any Fire Alarm
60 = AAV Trigger
40 = Bypassing
61 = AVS/GSMV session begin §
41 = **AC Power Failure
62 = AVS/GSMV session end §
42 = **System Battery Low
66 = Function key†
43 = Communication Failure
67 = Bell Failure
52 = Kissoff
68 = TELCO Line Fault
54 = Fire Zone Reset
78 = Keyswitch red LED†††
79 = Keyswitch green LED†††
– 46 –
27 must be programmed with a House Code.
Event (for zone list/activated by)
By Zone List
By Zone No.
0 = restore
0 = restore
1 = alarm
1 = alrm/flt/trbl
2 = fault
3 = trouble
24 = Silent Burglary
77 = Keyswitch
81 = AAV Monitor Zone
90-91 = Configurable
Note: In normal operation mode:
Code + # + 7 + NN Key Entry starts Device
Code + # + 8 + NN Key Entry stops Device
** Use 0 (any) for Partition No. (P) entry.
*** Or at Disarming, whichever occurs earlier.
† Use *57 Menu mode to assign the function key.
†† Duration is set in program field *177.
††† Device action not used for these choices.
§ automatically set when appropriate AVS Quick
Command performed.
Action
Output
Device
0 = off
Number
Type
1 = close 2 secs
2 = stay closed
V20P=1-18
R = relay
3 = pulse
T = trigger
4 = toggle
V15P=1-8,
X = X10
5 = duration 1
17, 18
††
6 = duration 2
††
§§ when used with an output function,
the carbon monoxide zone type
activates only upon CO alarms. Does
not activate for trouble conditions.