Honeywell ADEMCO VISTA SERIES Programming Manual page 16

Hide thumbs Also See for ADEMCO VISTA SERIES:
Table of Contents

Advertisement

∗ ∗ ∗ ∗ 182
Configurable Zone Type 90
(0-9, #+10=10, #+11=11, #+12=12,
#+13=13, #+14=14, #+15=15).
∗ ∗ ∗ ∗ 183
Zone Type 90 Report Codes
90 ALARM ID: XXX
TROUBLE ID: XXX
Press [∗] when done to continue.
NOTE: Zone alarm report codes and
trouble report code (∗60) and relevant
restore codes must be enabled in order
to report configurable zone type codes.
∗ ∗ ∗ ∗ 184
Configurable Zone Type 91
(0-9, #+10=10, #+11=11, #+12=12,
#+13=13, #+14=14, #+15=15).
∗ ∗ ∗ ∗ 185
Zone Type 91 Report Codes
91 ALARM ID: XXX
TROUBLE ID: XXX
∗ ∗ ∗ ∗ 189
AUI Device Enables
(for TouchScreen Style Keypads)
VISTA-20P:
For Touchscreen device usage
0 = disable
1 = partition 1
2 = partition 2
3 = partition 3 (common)
For Remote Services device usage
5 = part. 1 (auto-stay arm disabled)
6 = part. 2 (auto-stay arm disabled)
7 = part. 3 (common; auto-stay arm
disabled)
VISTA-15P:
For Touchscreen device usage
0 = disable
1 = enable
For Remote Services device usage
5 = part. 1 (auto-stay arm disabled)
Device Addresses:
Touchscreen device 1: Must set to 1
Touchscreen device 2: Must set to 2
Touchscreen device 3: Must set to 5
Touchscreen device 4: Must set to 6
KEYPAD OPTIONS *190-*196
To enable keypads:
1. Set desired address at keypad (refer to keypad's instructions for setting the address).
2. Use data fields *190-*196 to enable keypad addresses, assign a partition, and enable sound options.
3. Use fields *197, *198, and *199 to turn on partition number display, exit time interval display, and select fail display mode.
4. Set keypad-related data fields as appropriate: *21 Quick Arm Enable, *23 Forced Bypass, *84 Auto STAY Arm
NOTES: 1. Options for keypad 1, address 16, are set by the factory and cannot be changed.
2. Each keypad must be assigned a unique address. Keypads programmed with the same address will give
unpredictable results.
1
2
3
4
5
Enter the appropriate value for each entry, 1-10, based on the charts
provided in the Configurable Zone Type Worksheet section. Each entry
is the sum of the values of its selected options
To calculate the value for each entry, add the values of the selected
options in each of the entry's columns shown in the respective chart
(one option per column). For example, to program entry 2 for "alarm
response to short," "auto restore on," but not a "vent zone," enter 5 ("1"
for alarm short + "4" for auto restore-yes + "0" for vent zone-no).
UL: Do not configure zones as a fire alarm or UL burglar alarm zone.
Enter the desired 3-digit Contact ID® report codes for alarms and
troubles occurring on zones assigned to this zone type. Enter the
codes sequentially (all 6 digits). When entering digits, [#] moves cursor
back, [∗] moves forward.
Important Notice on Report Codes: To avoid confusion at the central
station, it is recommended that existing Contact ID® codes be used
with configurable zone types whenever possible. Check with the central
station for a complete list of Contact ID® report codes. If none of the
codes are suitable, choose a code in the reserved range of 750-789
and make sure to define the code with your central station.
1
2
3
4
5
See ∗182 for entries.
UL: Do not configure zones as a fire alarm or UL burglar alarm zone.
See ∗183 for entries.
[1, 1, 0, 0]
AUI 1
AUI 2
AUI 3
AUI 4
System supports touchscreen style keypads (e.g., Symphony
Advanced User Interface, and 6270 Touchscreen Keypad; V20P = up
to 4; V15P = up to 2).
NOTE: Use of touchscreen style keypads does not affect the number of
standard keypads supported.
AUI Compatibility Note: To ensure proper AUI device operation, use AUI
devices with the following rev levels: 6270 series use version 1.0.9 or higher;
8132/8142 (Symphony) series use version 1.1.175 or higher.
To enable a touchscreen keypad, enter the option corresponding to
each touchscreen's home partition.
Note for Remote Services Devices: If using the Remote Services
feature of the communication device, select an option 5-7, depending
on the partition the Remote Services device is associated with (these
options automatically disable auto-stay arming when the system is
armed from the respective Remote Services device). Refer to the
communication device's installation instructions for details on enabling
the Remote Services feature.
Note for Remote Services Device Address: Using an AUI device
address for Remote Services provides enhanced remote services
features, but an actual AUI device is not used. If no AUI addresses are
available (all four AUIs are being used), choose an available standard
keypad address and use the appropriate keypad address field ∗190 -
∗196 to select the Remote Services operating partition (some remote
access features will be unavailable).
– 16 –
6
7
8
9
10
6
7
8
9
10