Zone List Menu Mode - Honeywell ADEMCO VISTA SERIES Programming Manual

Hide thumbs Also See for ADEMCO VISTA SERIES:
Table of Contents

Advertisement

"C"
01 Enter Zn No.
12
01 Output Action
Close for 2 sec
1
Enter Output No.
R02
02
02
A E P TRIG
R02 1 1
3 ZL=00
∗ ∗ ∗ ∗ 81 ZONE LIST MENU MODE
(press *81 while in Programming mode) The Zone List Worksheet is on page 45.
Zone lists let you group individual zones for use with certain system actions. Using this mode, simply select an appropriate
zone list number, then add the desired zone numbers to be included in that list.
The following table shows the available zone lists and their purposes:
List No.
Used for...
1, 2
general purpose (GP)
3
chime-by-zone
4
cross zones (see note at right)
5
night stay zones
6
general purpose
V20PSIA/V15PSIA
7
general purpose
V20PSIA/V15PSIA
8
general purpose
9
zones that activate Pager 1
10
zones that activate Pager 2
11
zones that activate Pager 3 (VISTA-20P)
12
zones that activate Pager 4 (VISTA-20P)
*81 Menu Mode
Zone List No.
(00 = Quit)
01
01 Enter Zn Num.
(00 = Quit)
00
01 Del Zn List?
0 = No 1 = Yes
0
Zone Number
Press [ , ] to continue.
Output Action
0 = off
1 = Close for 2 seconds
2 = Stay Closed
3 = Pulse on & off (1 sec
ON, 1 sec OFF)
4 = Change Device State
5 = Duration 1 (see data
field *177)
6 = Duration 2 (see data
field *177)
Press [ , ] to continue.
Output Number
01-16 = VISTA-20P outputs
01-08 = VISTA-15P outputs
17-18 = on-board triggers
Press [ , ] to continue.
Summary Screen
Press [ , ] to continue.
(see field *26 to enable option)
: dial delay disable
: unlimited reports
Zone List Number
01-12 = zone list number
[∗] to continue
Zone Number
01-64 † = zone numbers
followed by [∗] to
accept each zone
00 to continue
Deleting Zone Lists
0 = don't delete list
1 = delete this zone list
[∗] to continue
(prompt appears if zone number was selected)
Enter the desired zone number associated with this output
number. At the ENTER EVENT prompt, enter the zone event
that will activate this output.
01 Enter Event
0 = restore; 1 = alarm/fault/trouble
Restore
0
Press [ , ] to continue to the "Output Action" prompt
Enter the desired device action.
Enter the device output number (programmed in *79 Menu
Mode) you want associated with this output.
A summary screen appears showing the programmed settings.
Press [∗] to return to OUTPUT FUNCTION NUMBER prompt
Notes
• Any list may include any or all of the system's zone numbers.
• A zone list can be assigned to more than one output relay.
• Zone List 4: When creating zone list 4 for cross zoning,
include only zones assigned to zone types 3, 4, or 5. Do not
include zones that have delays (entry/exit zones, interior
w/delay) or 24-hour zones, as these zone types may produce
unpredictable operation and may not function as intended.
See field *85 for Cross Zone Timer option.
• Zone List 6:
V20PSIA/V15PSIA:
Disable option.
• Zone List 7:
V20PSIA/V15PSIA:
Reports option.
Enter the Zone List Number to program (or 00 to quit). Press [ , ]
to advance.
In the following displays, zone list 01 has been selected.
Enter each zone number to add to the zone list, followed by
pressing [ , ] (example, 01 , , 02 , , 03 , ). After all zones are
entered, press 00 to continue.
IMPORTANT: Do not include fire zones in zone lists that are
used to STOP device actions.
† VISTA-20P = 01-64; VISTA-15P = 01-06, 09-34, 49-56.
To delete the zone list, enter 1. All zones in the zone list will be
deleted automatically and the system returns to the Zone List
No. prompt.
To save the zone list, enter 0.
– 28 –
See field *50 for Dial Delay
See field *93 for Unlimited