Faults
Fault
Compressor system
does not start up
Oil in suction filter
Excessive oil
consumption
Safety valve blows
System pressure does
not decrease when
switching off
Page 42
5.2
Possible cause
No electric power to compressor
Fuses are defective
Machine has not vented perfectly
Voltage fluctuations in the electri-
cal mains power
Compressor oil is very viscous due
to low ambient temperature
Minimum pressure non-return
valve is leaking
Suction controller is leaking
Switch-off performed by emer-
gency-off switch/button
Drain line is blocked
Defective oil separator element
Excessive oil filling
Operating pressure target value
maladjusted
Defective safety valve
Venting valve does not open
Check valve is leaking
Faults – Compressor
Rectification
Check electrical connection
Check the mains and control fuses, replace if necessary
Check venting valve and replace, if necessary
Ensure constant voltage
Heat compressor room
Check the minimum pressure check valve and replace, if necessary
Check the suction controller and replace, if necessary
Cut-out normally via O-key
Dismantle and clean drain line
Check oil separator and replace, if necessary
Drain off oil
Set operating pressure to maximum permissible pressure of the
screw compressor
Replace safety valve
Check the venting valve and replace, if necessary
Examine check valve and replace, if necessary
BOGE Operating instructions for C 15 series screw compressors

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C 15 and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

C 15 f

Table of Contents

Save PDF