Part 5: Faults
Fault
No quantity delivered,
no pressure build-up,
max. pressure 7 psig
BOGE Operating instructions for C 15 series screw compressors
5.1
5.1 General
The tables on the following pages give information on the possible causes of
operating faults and measures for their rectification (please also refer to oper-
ating instructions of the compressor control).
WARNING!
Ensure that any work required to rectify faults is only carried out by trained
personnel or specialists.
Any performance of work on pressurized system components may be carried
out by duly qualified and specialized personnel only.
Ensure that components which have a safety function are only set, repaired
or exchanged by BOGE Service!
Please contact BOGE-Service at the following telephone numbers, if you
have any questions.
DANGER: Voltage!
Prior to any work required to rectify faults it is essential to take all necessary
safety precautions as described on page 5!
5.2 Faults – Compressor
Possible cause
System components in the
compressor are leaking
Minimum pressure valve is
defective
Electromagnetic venting valve
does not close
Suction controller does
not open
V-belts are torn
General
Telephone: +1-770-874-1570
Telephone: +49 5206 601-140
Rectification
Check oil and compressed air lines inside the compressor; tighten
and/or reseal screw connections, if necessary
Close ball valve and check whether pressure builds up; if so, open
ball valve again immediately; replace minimum pressure valve
Check solenoid valve and replace, if necessary
Suction controller or solenoid valve is defective; check and replace,
if necessary
Fit new V-belts