Installation
Checking compressed
air outlet for tightness
Opening the stop valves
BOGE Operating instructions for C 15 series screw compressors
3.5
Changing the rotational direction
WARNING: Risk of injury!
–
Switch off the compressor using the OFF button.
–
Actuate emergency-stop switch/button.
–
Open mains disconnecting device.
–
Secure mains disconnecting device against unintentional switch-on.
–
Check to ensure that all machine elements are definitely currentless.
–
Cover or block off adjacent energized parts.
–
Interchange two phases (L1, L2 or L3) in the power cable.
WARNING: Risk of injury!
Work on the compressed air system may only be carried out by experienced
and authorized qualified personnel!
Always wear protective clothing and goggles!
Immediately after having switched on the machine the connection of the com-
pressed air outlet must be checked for tightness!
Make sure to observe an appropriate safety distance during the inspection!
–
Close mains disconnecting device.
–
To conduct the inspection switch on the compressor and check the com-
pressed air outlet for tightness.
–
Switch off compressor.
WARNING: Risk of injury!
Prior to any maintenance and servicing work take all necessary safety pre-
cautions as described on page 5.
–
If necessary, have leakages repaired by skilled qualified pesonnel.
–
List up the test results in the commissioning certificate.
Open ball valve on the compressor delivery.
Commissioning
Page 35