10a. Settings and Capacities in liters

Coffee and Vending machines
Coffee-Espresso
°Clarke
°KH
PPM
°FH
(GB)
< 6
8
107
11
7
9
125
13
8
10
143
14
9
11
161
16
10
13
179
18
11
14
196
20
12
15
214
21
13
16
232
23
14
18
250
25
15
19
268
27
16
20
286
29
17
21
304
30
19
24
339
34
21
26
375
38
23
29
411
41
26
33
464
46
29
36
518
52
33
41
589
59
38
48
679
68
The COFFEE-ESPRESSO application describes the production of hot drinks with
steam operation. The stated capacities are intended as guidelines for single cup
dispense. The capacities may vary according to dispensed volume and machine
type. Please contact us for recommendations.
Combi Steamers / Self-Cooking Systems / Steam Cookers / Ovens
Direct Injection
°Clarke
°KH
PPM
°FH
(GB)
< 6
8
107
11
7
9
125
13
8
10
143
14
9
11
161
16
10
13
179
18
11
14
196
20
12
15
214
21
13
16
232
23
14
18
250
25
15
19
268
27
16
20
286
29
17
21
304
30
19
24
339
34
21
26
375
38
23
29
411
41
26
33
464
46
29
36
518
52
33
41
589
59
38
48
679
68
Capacities are intended as guidelines and can vary according the machine typ.
Please contact us for recommendations.
capacity in liters
Bypass-
levels
S
M
L
5
3'000
4'350
8'400
4
2'140
3'570
6'000
4
1'870
3'120
5'250
4
1'670
2'780
4'670
4
1'500
2'500
4'200
3
1'170
1'950
3'270
3
1'070
1'790
3'000
3
990
1'650
2'770
3
920
1'530
2'570
3
860
1'430
2'400
3
800
1'340
2'250
3
760
1'260
2'120
3
680
1'130
1'900
2
540
890
1'500
2
490
810
1'370
2
430
720
1'210
2
390
650
1'090
2
340
570
950
2
300
490
830
capacity in liters
Bypass-
levels
S
M
L
0
1'500
2'500
4'170
0
1'290
2'140
3'570
0
1'130
1'880
3'130
0
1'000
1'670
2'780
0
900
1'500
2'500
0
820
1'360
2'270
0
750
1'250
2'080
0
690
1'150
1'920
0
640
1'070
1'790
0
600
1'000
1'670
0
560
940
1'560
0
530
880
1'470
0
470
790
1'320
0
430
710
1'190
0
390
650
1'090
0
350
580
960
0
310
520
860
0
270
450
760
0
240
390
660
Vending
°Clarke
°KH
PPM
(GB)
XL
8'700
< 6
8
107
8'570
7
9
125
7'500
8
10
143
6'670
9
11
161
6'000
10
13
179
4'670
11
14
196
4'290
12
15
214
3'960
13
16
232
3'670
14
18
250
3'430
15
19
268
3'210
16
20
286
3'020
17
21
304
2'710
19
24
339
2'140
21
26
375
1'960
23
29
411
1'730
26
33
464
1'550
29
36
518
1'360
33
41
589
1'180
38
48
679
The VENDING application describes the production of hot drinks without steam
operation. The stated capacities are intended as guidelines for single cup
dispense. The capacities may vary according to dispensed volume and machine
type. Please contact us for recommendations.
Boiler System
°Clarke
°KH
PPM
(GB)
XL
6'000
< 6
8
107
5'140
7
9
125
4'500
8
10
143
4'000
9
11
161
3'600
10
13
179
3'270
11
14
196
3'000
12
15
214
2'770
13
16
232
2'570
14
18
250
2'400
15
19
268
2'250
16
20
286
2'120
17
21
304
1'890
19
24
339
1'710
21
26
375
1'570
23
29
411
1'380
26
33
464
1'240
29
36
518
1'090
33
41
589
950
38
48
679
Capacities are intended as guidelines and can vary according the machine typ.
Please contact us for recommendations.
13
capacity in liters
Bypass-
°FH
levels
S
M
11
6
3'540
4'350
13
5
2'430
4'290
14
5
2'120
3'750
16
5
1'890
3'330
18
5
1'700
3'000
20
4
1'290
2'270
21
4
1'180
2'080
23
4
1'090
1'920
25
4
1'010
1'790
27
4
940
1'670
29
4
880
1'560
30
4
830
1'470
34
4
750
1'320
38
3
580
1'020
41
3
530
930
46
3
470
820
52
3
420
740
59
3
370
650
68
3
320
560
capacity in liters
Bypass-
°FH
levels
S
M
11
3
2'140
3'570
13
3
1'840
3'060
14
2
1'410
2'340
16
2
1'250
2'080
18
2
1'130
1'880
20
2
1'020
1'700
21
2
940
1'560
23
2
870
1'440
25
2
800
1'340
27
2
750
1'250
29
2
700
1'170
30
2
660
1'100
34
2
590
990
38
1
480
790
41
1
430
720
46
1
380
640
52
1
340
570
59
1
300
510
68
1
260
440
L
XL
8'700
8'700
7'140
8'700
6'250
8'700
5'560
8'000
5'000
7'200
3'790
5'450
3'470
5'000
3'200
4'610
2'980
4'290
2'780
4'000
2'600
3'750
2'450
3'530
2'190
3'160
1'700
2'450
1'550
2'240
1'370
1'980
1'230
1'770
1'080
1'560
940
1'180
L
XL
5'950
8'570
5'100
7'350
3'910
5'630
3'470
5'000
3'130
4'500
2'840
4'090
2'600
3'750
2'400
3'460
2'230
3'210
2'080
3'000
1'950
2'810
1'840
2'650
1'640
2'370
1'320
1'900
1'210
1'740
1'070
1'540
960
1'380
840
1'210
730
1'050

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Claris sClaris lClaris xl

Table of Contents