RequiRement
Bacterial Quality
Pressure
Temperature
Chlorine*
Production Flow Rate: 14.4 gpd (54 Lpd) @ 50 psig (340 kPa); 77˚ F (25˚ C)
Reject Flow Rate: 79.8 gpd (302 Lpd) @ 50 psig (340 kPa); 77˚ F (25˚ C)
*NOTE: Chlorine influent to Cartridge "B". For Cold Water use Only.
COntaminant ReduCtiOn
Contaminant
Total Dissolved Solids
Based on an RO Processor operating at 500 - 2000 mg/ L TDS; 40-70 psi; Neutral pH; Temperature 70 - 74˚ F; and a new Cartridge "B".
Congratulations on the purchase of your new ROM II or ROM III
Reverse Osmosis Modular Drinking Water System. You and your
family are about to enjoy better tasting, healthier water than
you ever thought possible. The ROM II uses superior design and
contaminant reduction performance of the prefilter cartridge with
a quick-change reverse osmosis cartridge. The ROM III blends the
proven superior design and contaminant reduction performance
of Everpure's ROM II Processor with a third cartridge for superior
performance in reducing volatile organic chemicals.
The result is the best available combination of technologies to
reduce aesthetic contaminants such as dirt, minerals, tastes and
odors; and health related contaminants such as sodium, heavy
metals and organics (VOC's).
PaRtS SuPPLied
1. ROM II Head assembly / ROM III Head assembly
2. Cartridge "A" (S-101)
3. Cartridge "B" (TFC RO)
4. Cartridge "C" (VOC#1) (ROM III only)
5. EV312118 - Flow Restrictor Kit ROM II & III
6. EV310876 - Flush plug (1 w/ROM II, 2 w/ROM III)
7. EV305061 - Red 1/4" tubing
8. EV544600 - Blue 3/8" tubing
9. EV311659 - Reducing tee
10. EV311660 - T-link valve
11. EV311588 - Tank Kit
12. EV311652 - Faucet Kit
13. EV312731 - Fitting - Faucet
Installation and Operation Guide
maximum
minimum
Potable
Potable
125 psig (860 kPa)
40 psig (280 kPa)
100˚F (38˚C)
40˚F (4˚C)
0 ppm (mg/L)
0 ppm (mg/L)
uSePa mCL
ROm ii average % Reduction
187
94.6
nOte: Read and save this manual.
The pages that follow will help you install your system. The
ROM II or ROM III System supplied by Everpure contains a
processor, storage tank, air-gap faucet, and drain connector.
This instruction manual details the installation for a typical
residential reverse osmosis application, but the ROM II or ROM
III System may be used with alternate equipment, such as a water
cooler. Manuals supplied with other components should also be
consulted during the installation. Read all manuals first to get a
clear picture of your project before you begin.
Outlined on page 7 of this manual are several maintenance
procedures you will need to do to guarantee optimum
performance of your system. Page 9 contains a troubleshooting
guide to assist in diagnosing operational problems if they arise.
ROM II and ROM III
ROm iii average % Reduction
94.6
EV3080-17 Rev H DE09

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ROM III and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Everpure ROM III

  • Page 1 Based on an RO Processor operating at 500 - 2000 mg/ L TDS; 40-70 psi; Neutral pH; Temperature 70 - 74˚ F; and a new Cartridge “B”. Congratulations on the purchase of your new ROM II or ROM III nOte: Read and save this manual.
  • Page 2: Drain Tubing

    SyStem OveRvieW - ROm ii aiR gaP FauCet PROduCt WateR tubing Sink FauCet COLd WateR FauCet Stub inLet WateR tubing tO POSt FiLteR (OPtiOnaL, nOt inCLuded) ROm PROCeSSOR RejeCt WateR tubing (Red) SuPPLy Fitting dRain tubing (t-Link) dRain COnneCtiOn COLd WateR SuPPLy tube S-101 PReFiLteR CaRtRidge “a”...
  • Page 3 SyStem OveRvieW - ROm iii aiR gaP FauCet PROduCt WateR tubing Sink FauCet COLd WateR FauCet Stub inLet WateR tubing tO POSt FiLteR (OPtiOnaL, nOt inCLuded) ROm PROCeSSOR RejeCt WateR tubing (Red) SuPPLy Fitting dRain tubing (t-Link) dRain COnneCtiOn COLd WateR...
  • Page 4: Storage Tank

    2. Determine the best location for components. S-101 PReFiLteR CaRtRidge “a” Cartridge “A” is the first cartridge in the ROM II or ROM III Processor. 3. Install the inlet water fitting. It serves two purposes. Most importantly, it adsorbs the chlorine that 4.
  • Page 5: Detailed Installation Instructions

    ROm PROCeSSOR 4. inStaLL the dRain COnneCtiOn The ROM III Processor measures approximately 12" wide x 17" high A 1-1/2" drain saddle has been provided with the system. x 4" deep and weighs about 9 pounds when operating. The ROM II Processor measures approximately 8"...
  • Page 6: Mount The Faucet

    OR OTHER SIMILAR SYMPTOMS. purchased at you local hardware store or home improvement center. I. For the ROM II installation, skip to step J. For the ROM III installation 9. inStaLL the OPtiOnaL POStFiLteR (not Supplied) only, install Cartridge “C” in the third head (C). Open the inlet shut-off It is recommended that a carbon postfilter be installed with the valve and and observe the flow from the air-gap faucet.
  • Page 7: Maintenance

    SanitiZe StORage tank The ROM II and ROM III System requires very little maintenance; there SANITIZE WITH EVERY CARTRIDgE CHANgE (EVERY SIX MONTHS) are no weekly or monthly procedures to follow. Regular cartridge Ensures good-tasting, high quality water. change is the only exception – and an important one.
  • Page 8 Shut-off Valve EV3103-91 Check Valve EV9273-77 Cartridge “A” (S-101) EV9273-70 Cartridge “B” (TFC RO) EV9273-79 Cartridge “C” (VOC #1) (Rom iii oNLy) EV3115-84 Flow restrictor EV3103-10 Reducer, 3/8" stem x 1/4" tube Not shown EV6500-57 8 Way Test Kit ROm ii ROm iii 1/4"...
  • Page 9: Troubleshooting

    E. Plugged Cartridge “A”. e. Replace Cartridge “A”. F. Plugged Cartridge “C”. (ROM III only) f. Replace Cartridge “C”. (ROM III only) g. Cartridge “B” fouled with sediment. g. Replace Cartridge “A” and Cartridge “B”.