DETECTION OF FAILURES
FAILURE
THE MACHINE DOES NOT
WORK
THE MACHINE OFTEN
BECOMES BLOCKED WHEN
EXTRACTING JUICE
THE DRUMS ARE NOT
SYNCHRONISED
THE EXTRACTORS BREAK
POSSIBLE CAUSE
Machine unplugged
No power supplied to socket
Switch not activated
Fuse blown
Cover not in proper position.
Information on display SEG 00010
Juice container not in proper
position. Information on display
SEG 00001
Peel container not in proper
position. Information on display
SEG 00010
Safety sensors dirty
Not enough voltage (Alarm 01)
Internal failure
Extractors not in right position
CORRECTION
Plug into mains
Check the socket
Activate the switch
Replace fuse in the connection
base (Fig. 2)
Check it is in the right position
Check it is in the right position
Check it is in the right position
Clean the button cover
Check that the voltage is within the
limits indicated in the manual
Notify the Technical Service
Put them in position in accordance
with the manual (Fig. 10)