Pump Set up – Mixer Shower 22mm (2)
4. Pump speed - Fine setting:
This setting may be required to fine tune the speed at flow
rates other than that used to set the main flow rate. The Fine
Speed adjustment corrects the flow rate over a band 1 ltr/min
either side of the flow rate that is being calibrated.
Increase the flow from the shower to its maximum value (less
than 12 ltrs/min) in 2 ltrs steps. Watch the water level around
the shower gulley. If this is rising or falling over time make
adjustments until a constant level is observed then press OK
'
'. The pump will not stop but the adjustment displayed will
return to '0'
6 . 6
B
5 . 4 ( 1 2 . 0 ) L P M
F i n e
S p e e d
Now reduce the flow rate to minimum (approx 3 ltrs/min).
Again adjust as required to keep the water level around the
gulley constant or just falling slightly. Once this adjustment is
made press OK '
' to select.
A
2 . 4
B
1 . 5 (
F i n e
S p e e d
Adjustments to more finely matched flow rates or special
features of the shower, i.e. Boost settings, can be made if
required.
Once complete press > to exit and move onto the
next stage.