1.
SPECIFICATION
Model
Product
AK1005
Codes
No. of Sensors
Voltage
Electrical
Tinned wire ends
Connections
Materials
2.
PRINCIPLES OF OPERATION
Grey Waste Tank - Service Kits
The Grey Waste Tank enables the user to manage all grey waste on board easily, through one skin fi tting. The Intelligent Control sensor integrated into the tank lid
provides automatic operation of the grey waste pump. The sensor will detect water in the grey waste tank at a pre-determined level, and will automatically activate the
grey waste pump. When the tank is emptied, the switch will automatically turn the grey waste pump off . The 2 sensor models include a second sensor which can be
used to control a second grey waste pump. It is factory set to activate at a higher water level and will provide additional pumping capacity during periods of high infl ow to
the grey waste tank. Alternatively, the second sensor can be wired to a high level alarm, warning of a high water level within the grey waste tank.
Read the following carefully before installation.
WARNING: Please note that incorrect installation may invalidate warranty.
3.
TO THE FITTER & TO THE USER
To the Fitter:
Check that the product is suitable for the intended application, follow these installation instructions and ensure all relevant personnel read the points listed below. Also
ensure that these operating instructions are passed on to the end user. The manufacturer cannot be held responsible for claims arising from incorrect installation,
unauthorised modifi cation or misuse of the product.
To the User:
Read the following instructions carefully.
4.
APPLICATION
The Grey Waste Tank is designed to collect grey shower waste water. If it is intended for use for any other purpose or with any other liquid, it is the user's responsibility
to ensure that the tank and switch are suitable for the intended use and, in particular, that the materials are fully compatible with the liquids to be used. The integrated
Intelligent Control sensor is designed to operate at 12V d.c or 24V d.c. only. The sensor is suitable for use with pumps operating with current up to 20A, and is
recommended for use with Whale Gulper® 220 or Gulper® 320 grey waste pumps.
5.
WARNINGS
• With all applications, it is important that a system of safe working practice is applied to installation, use and maintenance. Ensure the electric supply is turned off and
that the waste water system is drained before installation.
• The Grey Waste Tank is designed for the storage of grey waste water in recreational marine vessels. Your warranty may be invalidated if the product is used
in other applications or outside the remit of the standards quoted on the packaging/product literature.
• WARNING: Installation must be carried out by a qualifi ed electrician. Improper wiring can cause a fi re resulting in injury or death. Suggested wiring information (Figure
1A and Figure 1B) is given as a guide only, and wiring must comply in accordance with the applicable electrical standards. Appropriate size fuses or circuit breakers
must be installed.
Pump Model
Gulper 220 (12V dc)
Gulper 220 (24V dc)
Gulper 320 (12V dc)
Gulper 320 (24V dc)
Gulper IC (12V dc)
Gulper IC (24V dc)
Grey Waste Tank - Service Kits
AK1006
1
12V d.c. / 24V d.c.
1 x Deutsch
DT06-3S-P012
Seals: EPDM/Neoprene, Monprene®
Lid: Glass Filled Polypropylene, ABS, Polyurethane
AK1005 / AK1006 / AK1007 / AK1008
AK1007
AK1008
2
2 x Deutsch
Tinned wire ends
DT06-3S-P012
Recommended Automotive Fuse
Size (Amps)
5
2.5
10
5
10
5

Advertisement

loading

Summary of Contents for Whale AK1005

  • Page 1 Thank you for purchasing this Whale® product. For over 70 years Whale has led the way in the design and manufacture of freshwater, bilge and waste management systems including plumbing, taps, showers and pumps, for low voltage applications. The company and its products have built a reputation for quality, reliability and innovation backed up by excellent customer service.
  • Page 2 Grey Waste Pump connect to grey or secondary grey waste pump Figure 2A AK1005 / AK1006 Figure 2B AK1007 / AK1008 Instructions for Use Once installed, turn on shower or tap to fi ll grey waste tank. Ensure the pump is operating and waste water is being removed from the tank. Note: If using a seacock, ensure it is open before use.
  • Page 3 EMC Emissions EN55014-2:1997+A2:2008 EMC Immunity EN28846 :1993 Ignition Protection Richard Bovill Engineering Director PATENTS AND TRADEMARKS WHALE® and GULPER® are registered trademarks of Munster Simms Engineering Limited, Bangor, Northern Ireland trading as Whale. WARRANTY Discover other boat plumbing on our website.

This manual is also suitable for: