Pump Set-Up - Electric Shower 15Mm - Whale Digital Smoothflow Installation Manuallines

Kit
Table of Contents

Advertisement

Pump Set up – Electric Shower 15mm (1)
A simple setup is all that is required for trouble-free efficient
performance of the Digital Smoothflow system.
To adjust Settings:
or
These buttons switch between menu
options, indicated by the LCD message.
or
These buttons adjust the value.
The OK or Enter key (middle button) press to select and
store value.
Press OK '
' to enter configuration screens.
Follow the sequence of screens and set values as
required to complete setup.
System Type and Software level
S m o o t h f l o w
T o
S e t u p
P r e s s
Settings
1. Language: English is the default language. For
other options use
or
arrows.
L a n g u a g e
E n g l i s h
Press OK '
' to select.
2. Pipe size: Select 15mm for electric showers.
(Go to Page 15 for Mixer Set-up)
I n l e t
P i p e
S i z e
1 5 m m
Press OK '
' to select.
V 1 . 9
O K
O K
12
3. Sensor type: Select Venturi
S e n s o r
T y p e
V E N T U R I
Press OK '
' to select.
4. Pump speed: This enables the speed of the pump to
match the shower flow rate.
A
3 . 5
B
0 . 0
P u m p
S p e e d
Before making adjustments turn the shower on and wait until
the pump runs. Set the shower flow rate in the range 4 -7
ltrs/min as indicated on the display. The rate should remain
unchanged during set-up. Use
pump to match the flow rate.
Watch the level of water within the shower using the gulley
cover as a guide. If the water level is falling reduce the speed
of the pump by pressing . If the water level rises increase the
speed of the pump by using the
Note: After making a change wait for about '30' seconds, as the
system needs to stabilise. Watch the water level until you see if the
water is rising or falling before making the next adjustment.
Initially make changes in pump speed setting in increments
and decrements of 5 to quickly get to an approximate pump
speed that matches the flow rate. Once this is achieved make
finer adjustments, up or down, until the water level is slightly
over pumping. Store the speed setting by pressing OK '
The pump will stop whilst the setting is stored, and start again
at the set speed.
O K
3 . 5
L P M
0
or
to set the speed of the