Pairing Process - Pre Week 2 2019 (02/19) Page 7 Unpairing the transformer from the shower Page 8 Unpairing the shower from the transformer Section 2 Whale Instant Match Hardwired Connections (Mira, Triton and Redring) Page 9 Mira Hard Wired Connections Page 10 Triton Hardwired Connections and...
Page 3
Plumbing of the Waste Pipe A wireless Bluetooth connection may be used to allow the ® SDS236T (755.699 / 755.678) Whale Instant Match transformer to communicate with the Mira Advance Flex Extra (J09Nn or J09N) shower without the use of a physical hardwired connection or external flow sensor to activate the pump.
BEAB CARE MODE 43 DEG C 45 DEG C RESERVED 1 RESERVED 2 BLE PUMP ENABLE WIRED PUMP MODE Whale Transformer Settings Blue Jumper - Sensor Position 7 Grey Jumper - Over run 10 Seconds Red Jumper - Pipe inlet 15mm...
Page 5
Pairing Process Plumbing of the Waste Pipe 1. Transformer set up • Switch the mains electric supply to the transformer ON and wait to hear the audible beep from the transformer. The light on the transformer will now flash red to indicate ®...
Pairing Process - Pre Week 2 2019 (02/19). lumbing of the Waste Pipe Pairing setup for Mira Advance Flex Extra J09N Manufactured prior to Week 2 2019 1. Transformer set up • Switch the mains electric supply to the transformer ON and wait to hear the audible beep from the transformer.
Page 7
4. Slowly turn the dial on the shower to position 2 5. Pairing the shower to the Whale Instant Match transformer ® • Press and release the start/stop button on the shower. The status light on the shower will now flash blue to indicate that the shower is in pairing mode.
Page 8
PCB board may require the Bluetooth wireless technology ® connection between the shower and Whale Instant Match transformer to be terminated and paired again. To unpair the transformer from the shower, please follow these steps.
Page 9
• Remove front cover from Mira shower RESERVED 1 • Move DIP switch ‘BLE PUMP ENABLE’ to ‘ON’ position (see opposite) RESERVED 2 • Replace front cover BLE PUMP ENABLE WIRED PUMP MODE • The shower is ready to be paired with Whale transformer...
Compatible showers and their pump connections may be found below. Mira Advance Flex Extra 1.1785.005 (J09Nn or J09N) ® ® Wired Connections to the Whale Instant Match Transformer Ensure all LK settings are set to ‘OFF’ for hardwired connection BEAB CARE MODE...
DIGITAL PUMP SETTING Connect the control wire from the = 2200 PULSES / LITRE Omnicare Ultra Plus DIGI Whale Instant match as below: 1 - +5V (Red) 2 - 0 V (Black) 3 - Signal (Brown) Wired Connections to the Whale ®...
Page 12
Redring Hardwired Connections Redring Selectronic WP ® (RSEL85WPC or RSEL95WPC) Wired Connections to the Whale ® Instant Match Transformer ® Redring Shower Connections and Settings Redring Shower Connections and Settings ® Whale Transformer Settings Blue Jumper - Sensor Position 4...
Whale Instant Match Transformer Plumbing of the Waste Pipe ® Flow Sensor Connections An external flow sensor should be used where a shower is not compatible with ® a Bluetooth wireless technology or hardwired connection to activate the pump. Compatible flow sensors and their connections to the transformer are listed below.
In a situation where a Bluetooth wireless technology or hardwired connection with the shower cannot be established, or a suitable flow sensor has not been fitted, the Whale SDS236T Instant Match transformer can be used with an AK1568 flow switch to activate the pump.
Page 15
Whale Instant Match Transformer ® Flow Switch Connections Cont'd Mixer Shower Settings Step 1: Turn Dip switch 2 to the 'ON' position. Step 2: Move red jumper to pipe size '2' for 22mm inlet pipe. Step 3: Move the blue jumper to increase or decrease the pump speed as required, using the below table as a guide.
Need help?
Do you have a question about the SDS236T and is the answer not in the manual?
Questions and answers