Pump Set-Up - Mixer Shower 22Mm - Whale Digital Smoothflow Installation Manuallines

Kit
Table of Contents

Advertisement

Pump Set up – Mixer Shower 22mm (1)
A simple setup is required for trouble-free efficient
performance of the Digital Smoothflow System.
To adjust Settings:
or
These buttons switch between menu options, indicated
by the LCD message.
or
These buttons adjust the value.
The OK or Enter key (middle button) press to select and store
value.
Press OK '
' to enter configuration screens. Follow the
sequence of screens and set values as required to complete
setup.
Smoothflow
System Type and Software level
S m o o t h f l o w
T O
S E T U P
P R E S S
Settings
1. Language: English is the default language.
For other options use
or
L a n g u a g e
E n g l i s h
Press OK '
' to select.
2. Pipe size: Press
to select 22mm for
\mixer valve installations.
I n l e t
P i p e
S i z e
2 2 m m
Press OK '
' to select.
V 1 . 9
arrows.
O K
O K
3. Sensor type: Select Venturi
S e n s o r
T y p e
Press OK '
' to select.
4. Pump speed: This enables the speed of the pump to
match the shower flow rate.
A
3 . 1
B
P u m p
S p e e d
Before making adjustments turn the shower on and wait until
the pump runs. Set the shower flow rate in the range 7-9
ltrs/min as indicated on the display. The rate should remain
unchanged during set-up. Use
pump to match the flow rate. Watch the level of water within
the shower using the gulley cover as a guide. If the water level
is falling reduce the speed of the pump by pressing . If the
water level rises increase the speed of the pump by using the
button.
Note: After making a change wait for about '30' seconds, as the
system needs to stabilize. Watch the water level until you see if the
water is rising or falling before making the next adjustment.
Initially make changes in pump speed setting in increments
and decrements of 5 to quickly get to an approximate pump
speed that matches the flow rate. Once this is achieved make
finer adjustments, up or down, until the water level is slightly
over pumping. Store the speed setting by pressing OK '
The pump will stop whilst the setting is stored, and start again
at the set speed.
15
O K
V E N T U R I
5 . 6
8 . 7
L P M
0
or
to set the speed of the
'.

Advertisement

Table of Contents
loading

Table of Contents