Plumbing Gulley

• Before running water through the system ensure that
the shower area and gulley are completely free of debris.
• For pump mounting instructions. See Fig 2.3, Page 7
Orientate gulley so that it exits towards the pump inlet
to avoid unnecessary bends.
• When fitting in solid floors if copper pipe is used, it must be
sheathed to prevent corrosion.
Tray Gulley
• The tray gulley has a 35 mm profile to enable the shower
drain to fit into a screed floor without penetrating the
damp-proof membrane. See Fig 1.7
• Use silicone on top of the seal to ensure proper sealing
beneath tray.
• Use the hand tool provided to tighten the locking flange.
See Fig 1.8
• Fit the gulley cover into the sockets and push down to
secure. See Fig 1.9
Top Tip: Leave the hand tool in place to prevent building debris,
grout etc. falling into the gulley. Only remove the hand tool and fit
the gulley cover when the installation is complete and the shower
area has been thoroughly cleaned.
Wetfloor Gulley
• The wet floor gulley has a 40 mm profile to enable it to fit
into a screed floor without penetrating the damp-proof
membrane. See Fig 2.0
• Where no tray former is used the gulley has two lugs either
side of the discharge pipe to enable the gulley to be fixed
to the floor whilst screed is laid around the gulley.
• Where a tray former is used these lugs can be broken off
easily and the gulley mounted into the
160 mm gulley opening.
• The gulley has a conventional clamping ring to
accommodate vinyl flooring.
• The gulley cap clicks into place and may be easily removed
for cleaning if required.
Other Gulley's
• The pump may be used with gravity style gullies. Use
reducing couplings to achieve 22mm pipe run to pump.
1.7
1.8
1.9
2.0