Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Frame Assembling
WARNING: The columns of this table
base contain high force springs that
are sized to lift the worksurface
and accessories. If the release
lever is activated when the table is
inverted, or before the worksurface
is installed, the lack of weight on
the columns will allow the columns
to extend suddenly with great force.
Sudden extension will damage
the table and could cause serious
injury.
DO NOT REMOVE SAFETY PIN
(RING) OR WARNING TAG UNTIL
TABLE IS COMPLETELY ASSEMBLED
AND IN THE UPRIGHT POSITION.
Tools Required:
#2 Phillips Screwdriver
#3 Phillips Screwdriver
5mm Hex Key
6mm Hex Key
Note: Before discarding any packaging,
confirm all components received against
the packing list.
Note: Assembly should be done on a
clean, flat, and soft, surface.
1. Position the folded frame assembly as
illustrated, onto a clean soft surface.
Rotate the top-most of the two columns up
vertically until the two tapped holes in the
column align with the frame channel holes
(Figure 1 & Detail B).
2. Loosely insert two M8 x 14mm screws
from the outside, at each side of the frame
support bracket, through the frame channel
holes and into the inner tapped holes.
Do not tighten at this time
(Figure 1 & Detail B).
Note: See Detail A of the lower-folded
column to identify the tapped hole of the
column, and the frame channel holes
which are similar for the "top-most"
column of Detail B.
3. Locate the two pivot screws, one on each
side of the frame assembly. Using a
6mm Hex Key, tighten both pivot screws,
then tighten each of the four installed
screws from step 2 above. Tighten all
screws to 7 ft/lbs (Figure 2).
4. Repeat the steps above for the second
column (Figures 1 & 2, Details A & B).

Advertisement

loading

Summary of Contents for KI CB

  • Page 1 Assembly Instructions WorkUp Adjustable Table ® Frame Assembling Model CB WARNING: The columns of this table base contain high force springs that are sized to lift the worksurface and accessories. If the release August 2017 lever is activated when the table is...
  • Page 2 WorkUp Adjustable Table - Model CB ® Assembly Instructions Assemble units as described herein only. To do otherwise may result in instability. All screws, nuts and bolts must be tightened securely and must be checked periodically after assembly. Failure to assemble properly, or to secure parts may result in assembly failure and personal injury.
  • Page 3: Final Assembly

    WorkUp Adjustable Table - Model CB ® Assembly Instructions Assemble units as described herein only. To do otherwise may result in instability. All screws, nuts and bolts must be tightened securely and must be checked periodically after assembly. Failure to assemble properly, or to secure parts may result in assembly failure and personal injury.