The MC 1500 controller makes it possible to control up to two LED illuminations
(A and B). In order to keep the control panel clearly arranged and compact
separate operational controls for each unit A and B have been -dispensed with.
A changeover button takes their place:
By pressing the unit selector key (1) the MC 1500 operating controls are
routed to VisiLED unit A or B. The green LED indicators above key (1) display
which of the two illumination units (A or B) has been selected.
Only the selected VisiLED unit (A or B) can be set by the MC 1500 operation
controls! This applies to the segment setting (3), the light intensity setting
(5), the rotation setting (6) and the key (9) "Strobe on/off".
The LED displays (2) and (4) on the MC 1500 control panel show the settings
for the selected illumination unit only! The segment mode and the intensity
setting of VisiLED unit A and B cannot be read off concurrently, but rather
successively – by repeatedly pressing the key (1).
The illumination is not changed by solely pressing the selector key (1). In
particular the light of the VisiLED units is not switched on or off!
Synchronized rotation (see Section 8.4):
"Rotation of mixed light" and setting of "rotation speed"
Memory area (see Section 8.5):
"Storage of mixed light" and "Calling-up mixed light"
If just the storage of light from one of the two LED illuminations (A or B) is
required then the second LED unit should be dimmed down to intensity 0.
Strobe mode (see Section 8.6):
Setting of "Strobe frequency" and "Strobe pulse duration"
In this way "synchronized strobing" is guaranteed if both LED illuminations
are in strobe mode! Individual activation/deactivation of the strobe mode
using key (9) is possible for each LED illumination (see above).
Trigger mode (see Section 8.6):
"Trigger mode on/off" and "Trigger delay time" (time between trigger
pulse and light pulse)
8. MC 1500 operation
8.1 A/B unit selector key
Please note
All other MC 1500 settings affect
both illumination units