SCHOTT VisiLED MC 1500 Manual page 42

Table of Contents

Advertisement

Available languages

Available languages

40
Operating controls
GB
Several special functions like e.g.
flash mode can only be adjusted
via the PC
Subject to modifications and
amendments
2
1
8
A/B unit selector key with LED display
1
Only illumination parameters of the VisiLED
unit (A or B) selected using (1) can be set by
the key-board of the MC 1500! The LED indica-
tors of the MC 1500 display the settings of
the selected unit only. The illumination is not
affected by solely pressing the selector key.
LED display for segment setting
2
Shows the current segment mode of the
selected illumination unit A/B.
Select key for segment setting
3
Setting of segment mode for selected
unit A/B.
LED display for light intensity adjustment
4
Shows the relative brightness of the selected
unit A/B.
Keys for brightness adjustment
5
Keys for increasing/reducing the bright-
ness of the selected unit A/B. When
operating in activated -strobe or trigger
mode the keys (5) have special functions
(see Section 8.6).
Key for single step and continuous rotation
6
Single step rotation of the selected unit A/B by
pressing key (6). "On/off" continuous rotation
of selected unit A/B by holding down key (6)
for more than 2 seconds. "On/off" synchro-
nized rotation of illumination units A and B by
pressing or holding down key combination
(10) + (6). Under synchro-nized rotation the
set mixed light characteristics is retained.
3
4
5
6
9
5
10
Memory area
7
Memory keys M1 to M4 for calling
up stored illumination conditions.
Key combination (M) + (M1) to (M) +
(M4) for saving the currently set
mixed light.
Thermo guard
8
Red, blinking LED (8) warns of increased
tempera-ture of the illumination unit A
or B. When the maximum permitted
temperature is exceeded affected VisiLED
unit is switched off and display (8) is
permanently lit up.
„Strobe" key
9
Activation/deactivation of strobe mode
for the -selected illumination unit A/B.
Special functions when strobe mode
activated: Key (5): Setting of strobe
frequency; Key combination (10) + (5):
Setting of strobe pulse duration.
"Star" key
10
Only functions when pressed in combinati-
on with other keys.
"Trigger mode" key combination
9 10
Activation/deactivation of trigger mode
for the selected LED unit. Special functions
when trigger mode activated: Key (5):
Setting of duration between external
trigger pulse and light pulse.
7