40
Operating controls
GB
Several special functions like e.g.
flash mode can only be adjusted
via the PC
Subject to modifications and
amendments
2
1
8
A/B unit selector key with LED display
1
Only illumination parameters of the VisiLED
unit (A or B) selected using (1) can be set by
the key-board of the MC 1500! The LED indica-
tors of the MC 1500 display the settings of
the selected unit only. The illumination is not
affected by solely pressing the selector key.
LED display for segment setting
2
Shows the current segment mode of the
selected illumination unit A/B.
Select key for segment setting
3
Setting of segment mode for selected
unit A/B.
LED display for light intensity adjustment
4
Shows the relative brightness of the selected
unit A/B.
Keys for brightness adjustment
5
Keys for increasing/reducing the bright-
ness of the selected unit A/B. When
operating in activated -strobe or trigger
mode the keys (5) have special functions
(see Section 8.6).
Key for single step and continuous rotation
6
Single step rotation of the selected unit A/B by
pressing key (6). "On/off" continuous rotation
of selected unit A/B by holding down key (6)
for more than 2 seconds. "On/off" synchro-
nized rotation of illumination units A and B by
pressing or holding down key combination
(10) + (6). Under synchro-nized rotation the
set mixed light characteristics is retained.
3
4
5
6
9
5
10
Memory area
7
Memory keys M1 to M4 for calling
up stored illumination conditions.
Key combination (M) + (M1) to (M) +
(M4) for saving the currently set
mixed light.
Thermo guard
8
Red, blinking LED (8) warns of increased
tempera-ture of the illumination unit A
or B. When the maximum permitted
temperature is exceeded affected VisiLED
unit is switched off and display (8) is
permanently lit up.
„Strobe" key
9
Activation/deactivation of strobe mode
for the -selected illumination unit A/B.
Special functions when strobe mode
activated: Key (5): Setting of strobe
frequency; Key combination (10) + (5):
Setting of strobe pulse duration.
"Star" key
10
Only functions when pressed in combinati-
on with other keys.
"Trigger mode" key combination
9 10
Activation/deactivation of trigger mode
for the selected LED unit. Special functions
when trigger mode activated: Key (5):
Setting of duration between external
trigger pulse and light pulse.
7