Replacing Light Bulbs; Servicing The Burner - Montigo RP620 Series Installation & Maintenance Manual

Indoor gas fireplace
Hide thumbs Also See for RP620 Series:
Table of Contents

Advertisement

Replacing Light Bulbs
The RP620* light bulbs can be replaced in a few simple steps. Begin
by disconnecting the power to the fireplace. Follow the directions
for removing the screen and outer glass on page 30. Once the
screen and outer glass have been successfully removed, proceed
with figures 15 - 15b.
Note: Always wear gloves when handling the fireplace light bulbs
or glass panels.
STEP 1: Remove remove any decorative media and up-lighting glass
from the light kit tray.
STEP 2: To remove a light bulb, pull the light bulb away from the
light bulb connector and lift the light bulb up and out.
STEP 4: Rotate the newly replaced light bulb in a full circle.
STEP 5: Replace up-lighting glass in the burner tray.
XG0777 - 180525
Figure 15.
Figure 15.a
Figure 15.b
Servicing the Burner
STEP 1: Remove media, Lift one end of the rail up above the
firebox ceiling baffle. Pull the other end out the front of the
fireplace.
STEP 2: Remove 4 screws and then remove gas connection cover.
Figure 16.a
STEP 3: Disconnect the flexible gas connection line. After
removing the appropriate fasteners, remove burner assembly.
Figure 16.c
STEP 4: After removing the appropriate fasteners, remove the
burner assembly. Remove the valve cover to access to valves.
Figure 16.e
Appendix
Figure 16.
Figure 16.b
Figure 16.d
Figure 16.f
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rp620l-iRp620n-i

Table of Contents