Advertisement

Section 3-3-3: Heat Shields

Installing a Wall Mounted RHS101 Heat shield (5"/8")
The RHS101 Heat shield must be used if vent pipe passes through a
wall or ceiling within 6' of the unit.
To install the RHS101, Slide the Inner Section over the vent pipe that
will connect to the fireplace. Then fasten the vent pipe to the back of
the fireplace with a minimum of three sheet metal screws. From the
outside slide the RHS101 outer section on. To complete the installation
fasten the Heat Shield Outer Section & inner section to the structure.
See Figure 7.
⅜'' min.
⅜'' min.
Figure 7. RHS101 Installation. (Install by sliding over vent pipe where it passes through the
combustible construction).
16
⅜'' min. Both sides Typical
Inner shield 9 ⅜''
Outer shield 10 ¼''
Combustible Framing
Installing a Wall Mounted RHS102 Heat shield (5"/10")
The RHS102 Heat shield must be used if vent pipe passes through a
wall or ceiling within 6' of the unit.
To install the RHS102, Slide the Inner Section over the vent pipe that
will connect to the fireplace. Then fasten the vent pipe to the back of
the fireplace with a minimum of three sheet metal screws. From the
outside slide the RHS102 outer section on. To complete the installation
fasten the Heat Shield Outer Section & inner section to the structure.
See Figure 7.b
¼'' min.
¼'' min.
Figure 7.b RHS102 Installation. (Install by sliding over vent pipe where it passes through the
combustible construction).
Installation
¼'' min. Both sides Typical
Inner shield 11 ½''
Outer shield 10 ⅝''
Combustible Framing
XG0777 - 180525