Section 3-3-2: Venting Components

The following components and associated Montigo part numbers are for
installation of a roof or wall mounted termination. Use of non-Montigo
approved parts will VOID the warranty and may impede operation of
the fireplace.
A - Termination
PVHEX58-300 Wall Mount 5"/8"
PVHFL58-300 Flush Wall Mount 5"/8"
PVVEX58-300 Roof Mount 5"/8"
PVHEX510-300 Wall Mount 5'/10'
PVHFL510-300 Flush Wall Mount 5'/10'
PVVEX510-300 Roof Mount 5'/10'
B - Frame Kits
EPVRRF (Roof Mount 5"/10")
EPVRWF (Wall Mount 5"/10")
C - Flex Sections
PFL1 (12" f/f Section)
(5/8 Vent)
PFL2 (24" f/f Section)
PFL3 (36" f/f Section)
PFL4 (48" f/f Section)
PFL6 (72" f/f Section)
D - Rigid Sections
PXT - 10 (10" f/f Section)
(5/8 Vent)
PXT - 20 (20" f/f Section)
PEXT - 1 (12" f/m Section)
PEXT - 2 (24" f/m Section)
PEXT - 3 (36" f/m Section)
PEXT - 4 (48" f/m Section)
PEXT - 6 (72" f/m Section)
E - Elbows
PEL-90MM (m/m 90º Elbow)
(5/8 Vent)
PEL-90FF ( f/f 90º Elbow)
PEL-90FM ( f/m 90º Elbow)
PEL-45FM ( f/m 45º Elbow)
F - Support Ring &
PSPXT-8 (5/8 venting)
Plate
RSPXT-10 (5/10 venting)
G - Firestop
FS-8 (5/8 venting)
FS-10 (5/10 venting)
H - Heat Shield
RHS101 (5"/8")
RHS102 (5"/10")
IMPORTANT:
Please refer to your Building Envelope Engineer
or Waterproofing Consultant for a review of ALL
penetrations through exterior walls or the roof.
XG0777 - 180525
Notes For Planning Venting
• RP-Series fireplaces are Power Vent Designated and use Montigo's
5/8 vent pipes.
• Venting originates from the top or rear of the unit.
• Venting can terminate through the roof or exterior wall.
• Once the termination location has been established refer to the
appropriate section for installation details.
• All fireplaces are shipped Top Vent from the factory.
• Follow the chart on page 20 for maximum vent run and maximum
elbows.
Connection and installation of the vent
components should adhere to the following
guidelines:
• Use any combination of rigid and flex pipe as required and in any
orientation (Male connectors can face in any direction).
• Flex sections may be stretched up to 50% of their total length (e.g.
a 24" section maybe stretched to 36").
• Ensure the pipe ends male to female slide in a minimum of 1½" of
overlap.
• Connect all vent sections using a minimum of three sheet metal
screws on the outer pipe flue.
• Ensure all runs are supported with a minimum of 3 supports per
10' of venting.
• When hanging/ supporting venting, ensure that 1" clearance is
maintained on sides and bottom of vent runs and 2" above horizontal
vent runs to any combustible material.
• Rigid pipe may be cut less than half way from the FEMALE END ONLY.
• Ensure when cutting sections of rigid pipe to maintain integrity of
internal supports.
• Place the springs, supplied with the pipe kit, between the outer and
inner pipes to keep the pipes separate and avoid any possible hot
spots.
• Montigo recommends the use of a flex section for the final pipe
connected directly to the fireplace offering greater flexibility of
installation and absorption of movement.
• Firestops must be installed as required by National & local codes.
• When passing vent pipe through a wall use a heat shield.
• Montigo recommends that all exterior corners and joints be sealed
with exterior caulking. However, we encourage you to consult your
Building Envelope Engineer or Waterproofing Consultant for further
recommendations.