Status word 1
Displays active status word of variable speed drive (in binary) and can be used to diagnose
which commands are active.
Unit: -
Min: -
Bit fields:
Bit00
Bit01
Bit02
Bit03
Bit04
Bit05
Bit06
Bit07
Bit08
Bit09
Bit10
Bit11
Bit12
Bit13
Bit14
Bit15
P0970
Factory reset
P0970 = 1 resets all parameters to their default values.
Unit: -
Min: 0
Settings:
0=Disabled
Dependency:
First set P0010=30 (factory settings)
Stop drive (i.e. disable all pulses) before you can reset parameters to default values.
Note:
The following parameters retain their values after a factory reset:
P0918 (CB address),
P2010 (USS baud rate) and
P2011 (USS address)
P0971
Transfer data from RAM to EEPROM
Transfers values from RAM to EEPROM when set to 1.
Unit: -
Min: 0
Settings:
0=Disabled
Note:
All values in RAM are transferred to EEPROM.
Parameter is automatically reset to 0 (default) after successful transfer.
P1000[2]
Selection of frequency setpoint
Selects frequency setpoint source. In the table of possible settings below, the main setpoint is
selected from the least significant digit (i.e., 0 to 6) and any additional setpoint from the most
significant digit (i.e., x0 through to x6).
Unit: -
Min: 0
Data:
Selects frequency setpoint source. In the table of possible settings below, the main setpoint is selected from the least
significant digit (i.e., 0 to 6) and any additional setpoint from the most significant digit (i.e., x0 through to x6).
Example:
Setting 12 selects main setpoint (2) derived from analog input with additional setpoint (1) taken from the motor
potentiometer.
Settings:
1 Motor potentiometer setpoint
2 Analog input
Settings:
0=No main setpoint
1=MOP setpoint
2=Analog setpoint
3=Fixed frequency
4=USS on BOP link
5=USS on COM link
6=CB on COM link
7=Analog setpoint 2
10=No main setpoint + MOP setpoint
11=MOP setpoint + MOP setpoint
12=Analog setpoint + MOP setpoint
13=Fixed frequency + MOP setpoint
14=USS on BOP link + MOP setpoint
15=USS on COM link + MOP setpoint
16=CB on COM link + MOP setpoint
17=Analog setpoint 2 + MOP setpoint
20=No main setpoint + Analog setpoint
21=MOP setpoint + Analog setpoint
22=Analog setpoint + Analog setpoint
23=Fixed frequency + Analog setpoint
24=USS on BOP link + Analog setpoint
25=USS on COM link + Analog setpoint
26=CB on COM link + Analog setpoint
27=Analog setpoint 2 + Analog setpoint
30=No main setpoint + Fixed frequency
88/126
Siemens Building Technologies
HVAC Products
Motor potentiometer MOP up
Motor potentiometer MOP down
CDS Bit 0 (Local/Remote-Hand/Auto) 0
Def: -
Drive ready
Drive ready to run
Drive running
Drive fault active
OFF2 active
OFF3 active
ON inhibit active
Drive warning active
Deviation setp. / act. value
PZD control
Maximum frequency reached
Warning: Motor current limit
Motor holding brake active
Motor overload
Motor runs direction right
VSD drive overload
Def: 0
Def: 0
Def: 2
3 Fixed frequency setpoint
4 USS on BOP link
SED2 variable speed drives
Programming
0
NO, 1
YES
0
NO, 1
YES
NO, 1
YES
Max: -
0
NO, 1
0
NO, 1
0
NO, 1
0
NO, 1
0
YES, 1
0
YES, 1
0
NO, 1
0
NO, 1
0
YES, 1
0
NO, 1
0
NO, 1
0
YES, 1
0
NO, 1
0
YES, 1
0
NO, 1
0
YES, 1
Max: 1
1=Parameter reset
Max: 1
1=Start transfer
Max: 77
5 USS on COM link
6 Communication board (CB) on COM link
40=No main setpoint + USS on BOP link
41=MOP setpoint + USS on BOP link
42=Analog setpoint + USS on BOP link
43=Fixed frequency + USS on BOP link
44=USS on BOP link + USS on BOP link
45=USS on COM link + USS on BOP link
46=CB on COM link + USS on BOP link
47=Analog setpoint 2 + USS on BOP link
50=No main setpoint + USS on COM link
51=MOP setpoint + USS on COM link
52=Analog setpoint + USS on COM link
53=Fixed frequency + USS on COM link
54=USS on BOP link + USS on COM link
55=USS on COM link + USS on COM link
56=CB on COM link + USS on COM link
57=Analog setpoint 2 + USS on COM link
60=No main setpoint + CB on COM link
61=MOP setpoint + CB on COM link
62=Analog setpoint + CB on COM link
63=Fixed frequency + CB on COM link
64=USS on BOP link + CB on COM link
65=USS on COM link + CB on COM link
66=CB on COM link + CB on COM link
67=Analog setpoint 2 + CB on COM link
70=No main setpoint + Analog setpoint 2
Level 3
YES
YES
YES
YES
NO
NO
YES
YES
NO
YES
YES
NO
YES
NO
YES
NO
Level 1
Level 3
Level 1
CM1U5192en
01.2002

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents