Siemens SED2 series Operating Instructions Manual page 80

Variable speed drives
Hide thumbs Also See for SED2 series:
Table of Contents

Advertisement

Unit: -
Min: -
Bit fields:
Bit00
Bit01
Bit02
Bit03
Bit08
Bit09
Bit11
Bit12
Bit13
r0056
CO/BO: Status of motor control
Displays status of motor control (V/f status), which can be used to diagnose variable speed
drive status.
Unit: -
Min: -
Bit fields:
Bit00
Bit01
Bit02
Bit03
Bit04
Bit05
Bit06
Bit07
Bit08
Bit09
Bit10
Bit11
Bit12
Bit13
Bit14
Bit15
r0061
CO: Act. rotor speed
Displays current speed detected by encoder.
Unit: Hz
Min: -
r0086
CO: Act. active current
Displays active (real part) of motor current.
Unit: A Min: -
Dependency:
Applies when V/f control is selected in P1300 (control mode); otherwise, the display shows the value zero.
P0100
Europe / North America
Determines whether power settings (e.g. nominal rating plate power - P0307) are expressed in
[kW] or [hp].
The default settings for the nominal rating plate frequency (P0310) and maximum motor
frequency (P1082) are also set automatically here, in addition to reference frequency (P2000).
Unit: -
Min: 0
Settings:
0=Europe [kW], frequency default 50 Hz
1=North America [hp], frequency default 60 Hz
2=North America [kW], frequency default 60 Hz
Dependency:
The setting of DIP switch 2 under the I/O board determines the validity of settings 0 and 1 for P0100 according to the
following table:
DIP 2 Setting
Off
On
Stop drive first (i.e. disable all pulses) before you change this parameter.
P0010=1 (commissioning mode) enables changes to be made.
Changing P0100 resets all rated motor parameters as well as other parameters that depend on the rated motor
parameters (see P0340 - calculation of motor parameters).
Note:
P0100 setting 2 (==> [kW], frequency default 60 [Hz]) is not overwritten by the setting of DIP switch 2 (see table above).
r0200
Act. power stack code number
Identifies hardware variant
Unit: -
Min: -
Note:
Parameter r0200=0 indicates that no power stack has been identified.
r0206
Rated variable speed drive power [kW] / [hp]
Displays nominal rated motor power from the variable speed drive.
Unit: -
Min: -
Dependency:
Value is displayed in [kW] or [hp] depending on setting for P0100 (operation for Europe / North America).
r0207
Rated variable speed drive current
Displays maximum continuous output current of the variable speed drive.
Unit: A Min: -
r0208
Rated variable speed drive voltage
Displays nominal AC supply voltage of the variable speed drive.
Unit: V
Min: -
Value:
r0208=230 : 200 - 240 V +/- 10 %
80/126
Siemens Building Technologies
HVAC Products
Def: -
Fixed frequency Bit 0
Fixed frequency Bit 1
Fixed frequency Bit 2
Fixed frequency Bit 3
PID enabled
DC brake enabled
Droop
Not Used
External fault 1
Def: -
Init. control finished
Motor demagnetizing finished
Pulses enabled
Voltage soft start select
Motor excitation finished
Starting boost active
Acceleration boost active
Frequency is negative
Field weakening active
Volts setpoint limited
Slip frequency limited
F_out > F_max
Freq. limited
Phase reversal selected
I-max controller active
Vdc-max controller active
Vdc-min controller active
Def: -
Def: -
Def: 0
Meaning
[kW], frequency default 50 [Hz]
[hp], frequency default 60 [Hz]
Def: -
Def: -
Def: -
Def: -
SED2 variable speed drives
Programming
Max: -
0
NO, 1
0
NO, 1
0
NO, 1
0
NO, 1
0
NO, 1
0
NO, 1
0
NO, 1
0
NO, 1
0
YES, 0
Max: -
0
NO, 1
0
NO, 1
0
NO, 1
0
NO, 1
0
NO, 1
0
NO, 1
0
NO, 1
0
NO, 1
0
NO, 1
0
NO, 1
0
NO, 1
0
NO, 1
0
NO, 1
0
NO, 1
0
NO, 1
0
NO, 1
Max: -
Max: -
Max: 2
Overwrites
Overwrites
Max: -
Max: -
Max: -
Max: -
r0208=400 : 380 - 480 V +/- 10 %
YES
YES
YES
YES
YES
YES
YES
YES
NO
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
P0100 Setting
Meaning
1
[hp], frequency default 60 [Hz]
0
[kW], frequency default 50 [Hz]
r0208=575 : 500 - 600 V +/- 10 %
Level 3
Level 3
Level 3
Level 1
Level 3
Level 3
Level 3
Level 3
CM1U5192en