ABB PFTL 101 User Manual page 20

Pressductor pillowblock load cells horizontal measuring
Table of Contents

Advertisement

20
Pressductor PillowBlock Load Cells, Horizontal Measuring PFTL 101, User Manual
CAUTION
During this operation it is possible to over load the load cells if the operation is done not careful
enough, especially if the roll is heavy.
The most critical load cells are naturally the PFTL 101A-0.5 kN and PFTL 101B-2 kN.
Applications with inclined mounting are most critical.
6. Adjust the load cells so that they are in parallel with each other and in line with the axial direction
of the roll. Tighten the foundation screws, see
ment of Load Cells page
21.
7. Adjust the roll so that it is at right angles to the longitudinal direction of the load cells.Tighten the
screws in the upper adapter plate, see
Load Cells page
21.
Table 2 Tightening Torques for Load Cell PFTL 101
Option
Type of screws
1
Alloyed steel
(Recommended)
screws
Strength class
according to ISO
898/1
2
Alloyed steel
(Recommended)
screws
Strength class
according to ISO
898/1
3
Stainless steel
(A2-80)
or acid resistant
steel (A4-80),
Strength class
according to ISO
3506
4
Stainless steel
(A2-80)
or acid resistant
steel (A4-80),
Strength class
according to ISO
3506
Figure 15. Installation of Adapter Plates and Align-
Figure 15. Installation of Adapter Plates and Alignment of
Strength
Type of
class
lubrication
12.9
Oil
12,9
MoS
2
A2-80
Wax
or
A4-80
A2-80
Oil
or
or
A4-80
emulsion
3 Installation
Dimension
Tightening
torque
[Nm] ± 5%
M12
136
M16
333
M20
649
M12
117
M16
286
M20
558
M12
76
M16
187
M20
364
M12
65
M16
161
M20
313
3BSE009965R0401 en Rev E