Pressductor PillowBlock Load Cells, Horizontal Measuring PFTL 101, User Manual

Maintenance

General

Web/strip Tensiometer Systems with Pressductor
require daily servicing. As a preventive measure, checks should be done periodically on all parts
subject to mechanical wear.

Preventive Maintenance

Check mounting screws and tighten if necessary.
The gaps between load cell and plates should be checked to ensure that they do not get clogged
with dirt, causing shunt force past the load cell. Clean the gaps with compressed air if necessary.
The cable between the load cell and the junction box is subjected to possible damage and should
be checked and replaced if necessary.

Spare Parts

Users are recommended to keep the following spare parts in stock:
One load cell of correct type and size.
One connector complete with cable (for PTFL 101A and PFTL 101B).
Table 3 Ordering numbers for Load Cell PFTL 101
Description
Type
Load cell
PFTL 101A
Load cell
PFTL 101AE
Load cell
PFTL 101AER
Load cell
PFTL 101AER
Load cell
PFTL 101AER
®
load cells are extremely reliable and do not
Nominal load
Ordering numbers
(kN)
0,5
3BSE004160R1
1,0
3BSE004166R1
2,0
3BSE004172R1
0,5
3BSE004211R1
1,0
3BSE004212R1
2,0
3BSE004213R1
0,5
3BSE023010R1
1,0
3BSE023011R1
2,0
3BSE023012R1