5.4.2 Uploading Saved Parameters
If there is a "xxxx_yyy.cfg" file in the SD card with stored programmed parameters, then on
inserting the card, the Remote Control will ask to upload the Config File. Press Enter Button
to confirm or Back Key to cancel.
U p l o a d
c o n f ?
Y e s = E n t e r
N o = B a c k
U p l o a d
c o n f
1
%
SECTION 6 | Monitoring of Operation
TABLE 6.1 LED & BUZZER INDICATIONS FOR OPERATION MONITORING
Status
Seen during Power-On Sequence
Indicates completion of Power-On
Sequence after Power ON/OFF Button
is pressed for 2 sec
Seen during Power-Off Sequence
Indicates completion of Power-Off
Sequence after Power ON/OFF Button
is pressed for 5 sec
Normal charging
Equalization charging
Inverting
Low battery alarm
Power saving
Standby
Fault
NOTE: Buzzer is available only in EVO
EVO-RC-PLUS.
SD Card
• Asks to confirm or cancel uploading of saved parameters.
k e y
• Choose Yes by pressing Enter Key.
k e y
Configuration uploading.
Using LED and Buzzer
Blue LED "Status"
Blink 3 times
ON
Blink once per sec
Blink twice per sec
ON
ON
Blink once per 3 sec
Blink once per 5 sec
OFF
TM
OFF
ON
OFF
OFF
OFF
Blink once per sec
OFF
OFF
ON
Inverter/Charger. There is no buzzer in Remote Control
Red LED "Fault"
OFF
OFF
OFF
OFF
Beep per 3 second
(Default OFF)
Beep per second
OFF
OFF
ON
SAMLEX AMERICA INC. | 83
Buzzer (See Note 1)