SECTION 1 |
1.0 INTRODUCTION
The EVO-RC-PLUS Remote Control allows you to monitor and customize the operating pa-
rameters of Samlex EVO
HW, 2212, 2224, 3012 and 4024. Layout is shown in Fig 1 below.
It has its own internal Real Time Clock and Super Capacitor Type of Battery for clock operation.
1.1 LAYOUT AND DIMENSIONS
1.
LCD Screen:
- 4 rows of 20 characters each
- Blue screen with white
characters
2.
ON/OFF Key
3.
Blue LED "Status"
4.
Red LED "Alarm"
5.
Navigation Key "Back"
6.
Navigation Key "Up"
7.
Navigation Key "Down"
8.
Navigation Key "Enter"
9.
SD Card Slot – FAT16/32
format, up to 16 GB
10. RJ-45 Jack
Pin #
Signal
1
12V
2
12V
3
ON/OFF
4
D+
5
D-
6
NC
7
GND
1 2 3 4 5 6 7 8
8
GND
1 2 3 4 5 6 7 8
1.2 CONNECTING CABLE
Details of connecting cable provided with the Remote Control are as follows:
• Length: 10m / 33ft
• No of conductors: 8
• Modular Plug: 8P8C, RJ-45
• Plug interconnection: Straight (See Pinout at Fig 1.2)

Introduction and Layout

Inverter/Chargers Models EVO-1212F / 1212F-HW, 1224F / 1224F-
TM
11. RJ-12 Jack
Pin #
Signal
1
NC
2
GND
3
D-
4
D+
5
12
6
ON/OFF
123456
123456
View - Looking into the Jack)
1
3
2
Fault
4
Fig 1.1 Layout and dimensions of
Remote Control Model EVO-RC PLUS
View - Looking into the Jack)
160
146
5
6
7
10
11
128
SAMLEX AMERICA INC. | 3