Sony MVS-6530 Installation Manual page 18

2m/e, 3m/e multi format switcher processor
Hide thumbs Also See for MVS-6530:
Table of Contents

Advertisement

D2601 (C-1): SCU RESET
SCU CPU reset status indication.
. When S2601 is pressed.
. When Reset is requested from software.
. When IC4 does not start normally.
D1701 (G-1): NO LOCK status LED
REF IN status indication.
Lit when the format of signal that is input to the REF IN
terminal is different from the setting of switcher format.
D1702 (G-1): NO ALIGN status LED
Alignment status indication of internal REF signal gener-
ated from REF IN.
Lit when the alignment is not aligned.
D1703 (G-1) NO REF status LED
REF IN status indication.
Goes out when the REF signal is input to the REF IN
terminal. Lit when the REF signal is not recognized.
D2001 (H-1): SWR NIOS DONE status LED
Goes out when the configuration of SWR NIOS FPGA is
completed.
D3701 (G-1): SCU CADEC DONE status LED
Goes out when the configuration of SCU CADEC FPGA is
completed.
D3702 to D3705 (E-1): SCU_CADEC LED0, 1 to 3
Not used.
D3801 to D3804 (E-1): SCU_DBG LED1 to 4
Not used.
D3805 to D3820 (E-1): SCU STATUS
SCU CPU status indication.
D3903 (G-1): SCU NIOS DONE status LED
Goes out when the configuration of SCU CADEC FPGA is
completed.
D4101 (A-1), D4102 (A-1), D4103 (B-1):
SCU NIOS LED 1 to 3
SCU NIOS CPU status indication.
1-14 (E)
Switch
S501 (H-1): CA_RESET switch
Performs a reset of the CA-85 board alone.
S502 (H-1): RESET switch
Performs a reset of whole MVS processor and restarts it.
S503 (J-1): NIOSSIO_RESET
Performs a reset of SWR NIOS (IC2).
S601 (J-1): SWR MON
When pressing S501 and S502 while pressing this switch,
or when turning on the power, the CPU-DP module starts
in the monitor mode.
S2601 (C-1): SCU_RESET
Performs a reset of SCU CPU (IC3).
S2602 (C-1): NIOSBOX_RESET
Performs a reset of SCU NIOS (IC5).
S3501(C-1): SCU MON
When pressing S501 and S502 while pressing this switch,
or when turning on the power, the SCU CPU module starts
in the monitor mode.
S1301 (K-1): GROUP ID, UNIT ID switch
Switch to set GROUP ID and UNIT ID of the LAN con-
nection.
Bit 1 to 4 are for GROUP ID and bit 5 to 8 are for UNIT
ID setting.
Factory setting: Bit 1 and 5 are ON, others are OFF.
S1302 (J-1): SWR DGB SW switch
Not used.
S2201 (M-2): SW switch
For the operation mode setting of SWR NIOS (IC2).
Factory setting: Bit 1 is ON, others are OFF.
S3701 (C-1): SCU CADEC SW switch
Not used.
S3801 (E-1): STATION ID switch
Switch to set STATION ID of the SBUS connection.
Used when connecting the external routing switcher to the
SBUS terminal.
Factory setting: Bit 2 is ON, others are OFF.