Sony MVS-6530 Installation Manual page 25

2m/e, 3m/e multi format switcher processor
Hide thumbs Also See for MVS-6530:
Table of Contents

Advertisement

LED
D003 (C-1): +12V
+12V power status indication.
Lit when +12V is supplied.
D202 (C-1): +3.3V
+3.3V power status indication.
Lit when +3.3V is supplied.
D203 (C-1): +2.5V
+2.5V power status indication.
Lit when +2.5V is supplied.
D204 (C-1): +1.8V
+1.8V power status indication.
Lit when +1.8V is supplied.
D201 (C-1): +1.2V
+1.2V power status indication.
Lit when +1.2V is supplied.
D205 (C-1): +0.9V
+0.9V power status indication.
Lit when +0.9V is supplied.
D206 (C-1): REG
+1.2V-CADEC, +1.5V-A1 to 4, +1.1V-A1 to 4 power
status indication.
Lit when +1.2V-CADEC, +1.5V-A1 to 4 and +1.1V-A1 to
4 are supplied.
D701 (D-1): MV1
Status indication of IC005 FPGA configuration operation.
Goes out when the configuration of IC005 is completed.
If it does not go out, there may be a defect in IC005.
D702 (D-1): MV2
Status indication of IC006 FPGA configuration operation.
Goes out when the configuration of IC006 is completed.
If it does not go out, there may be a defect in IC006.
D703 (D-1): OUT1
Status indication of IC003 FPGA configuration operation.
Goes out when the configuration of IC003 is completed.
If it does not go out, there may be a defect in IC003.
MVS-6520
D704 (D-1): OUT2
Status indication of IC004 FPGA configuration operation.
Goes out when the configuration of IC004 is completed.
If it does not go out, there may be a defect in IC004.
D501 (D-1): CADEC
Status indication of IC001 FPGA configuration operation.
Goes out when the configuration of IC001 is completed.
If it does not go out, there may be a defect in IC001.
D401 (L-1): RESET
Status indication of RESET operation.
Goes out when RESET on the XPT-34 board is completed.
1-21 (E)